Related Experiment Video
Updated: Jan 31, 2026

Whole-body Mass Spectrometry Imaging by Infrared Matrix-assisted Laser Desorption Electrospray Ionization IR-MALDESI
Published on: March 24, 2016
An auxiliary matrix for routine analysis of small molecules and biological macromolecules using matrix-assisted laser
Zhangpei Zhu1, Jiajia Shen1, Dawei Wang2
1Key Lab of Drug Metabolism & Pharmacokinetics, State Key Laboratory of Natural Medicines, China Pharmaceutical University, Tongjiaxiang 24, Nanjing, 210009, China.
Abstract:
The great hurdles related with matrix-assisted laser desorption/ionization (MALDI) analysis are inhomogeneous crystallization, poor reproducibility, and low sensitivity. To effectively improve the performance of MALDI mass spectrometry (MS), graphene oxide (GO) was first utilized as an auxiliary matrix of the conventional matrices, including 2,5-dihydroxybenzoic acid (DHB), α-cyano-4-hydoxycyanocinnamic acid (CHCA), 2,4,6-trihydroxyacetophenone (THAP), and 3,5-dimethoxy-4-hydroxycinnamic acid (SA), for the analysis of small molecules and biological macromolecules on different MALDI MS systems. The results revealed that the DHB-GO composite matrix could provide much superior crystal homogenization, better reproducibility, higher sensitivity, and more excellent linearity for the statins' tissue imaging on iMScope than the single-use DHB matrix. Moreover, the DHB-GO dramatically improved the spot-to-spot and shot-to-shot reproducibility, crystal homogenization, sensitivity, and linearity of MALDI-TOF MS for statins' analysis in dried droplet. The capability of THAP on the analysis of lipids, similarly, could be greatly enhanced by the combined use of GO. THAP-GO composite matrix was expected to be widely used in the MALDI MS-based liposome studies. It was also found that CHCA-GO could provide superior analytical performance for peptides. The sensitivity and reproducibility of intact proteins could be greatly improved by SA-GO composite matrix. More importantly, the better reproducibility produced by the composite matrices sufficiently indicated that low concentration (0.1 mg mL-1) of GO almost did not cause contamination to MALDI MS system. Thus, GO was proved to be a versatile auxiliary matrix for the MALDI MS-based routine analysis of small molecules and biological macromolecules. Graphical abstract ᅟ.
More Related Videos
07:55Author Spotlight: A Tailor-Made Sample Preparation Approach for Enhanced MALDI-IMS Analysis of Hard Palm Seeds
Published on: June 30, 2023
09:38Dithranol as a Matrix for Matrix Assisted Laser Desorption/Ionization Imaging on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
Published on: November 26, 2013
Related Concept Videos
Matrix-Assisted Laser Desorption Ionization (MALDI)
Chemical Ionization (CI) Mass Spectrometry
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
The Extracellular Matrix
The Extracellular Matrix
In order to maintain tissue organization, many animal cells are surrounded by structural molecules that make up the extracellular matrix (ECM). Together, the molecules in the ECM maintain the structural integrity of tissue as well as the remarkable specific properties of certain tissues.
Composition of the Extracellular Matrix
The extracellular matrix (ECM) is commonly composed of ground substance, a gel-like fluid, fibrous components, and many structurally and functionally diverse...
Extracellular Matrix