Related Experiment Video
Updated: Jan 31, 2026

Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Virtual Noncalcium Dual-Energy CT: Detection of Lumbar Disk Herniation in Comparison with Standard Gray-scale CT
Christian Booz1, Jochen Nöske1, Simon S Martin1
1From the Division of Experimental and Translational Imaging (C.B., J.N., S.S.M., M.H.A., I.Y., L.L., T.D., J.L.W.) and Department of Diagnostic and Interventional Radiology (T.G.R., K.E., T.J.V.), University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany; and Department of Biomedical Sciences and Morphological and Functional Imaging, University of Messina, Messina, Italy (T.D.).
Abstract:
Purpose To assess the diagnostic performance of dual-energy CT with reconstruction of virtual noncalcium (VNCa) images for the detection of lumbar disk herniation compared with standard CT image reconstruction. Materials and Methods For this retrospective study, 41 patients (243 intervertebral disks; overall mean age, 68 years; 24 women [mean age, 68 years] and 17 men [mean age, 68 years]) underwent clinically indicated third-generation, dual-source, dual-energy CT and 3.0-T MRI within 2 weeks between March 2017 and January 2018. Six radiologists, blinded to clinical and MRI information, independently evaluated conventional gray-scale dual-energy CT series for the presence and degree of lumbar disk herniation and spinal nerve root impingement. After 8 weeks, readers reevaluated examinations by using color-coded VNCa reconstructions. MRI evaluated by two separate experienced readers, blinded to clinical and dual-energy CT information, served as the standard of reference. Sensitivity and specificity were the primary metrics of diagnostic performance. Results A total of 112 herniated lumbar disks were depicted at MRI. VNCa showed higher overall sensitivity (612 of 672 [91%] vs 534 of 672 [80%]) and specificity (723 of 786 [92%] vs 665 of 786 [85%]) for detecting lumbar disk herniation compared with standard CT (all comparisons, P < .001). Interreader agreement was excellent for VNCa and substantial for standard CT (κ = 0.82 vs 0.67; P < .001). VNCa achieved superior diagnostic confidence, image quality, and noise scores compared with standard CT (all comparisons, P < .001). Conclusion Color-coded dual-energy CT virtual noncalcium reconstructions show substantially higher diagnostic performance and confidence for depicting lumbar disk herniation compared with standard CT. © RSNA, 2018.
Related Concept Videos
Calculating Standard Free Energy Changes
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Cell Potential and Free Energy
Thermodynamics is the branch of physics dealing with the relationship between heat and other forms of energy. In an electrochemical cell, chemical energy is converted into electrical energy.