Related Experiment Video
Updated: Jan 31, 2026

Quantitative Metabolomics of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: January 5, 2021
Determination of testosterone and corticosterone in feathers using liquid chromatography-mass spectrometry
Zuzana Bílková1, Marie Adámková2, Tomáš Albrecht3
1Research Centre for Toxic Compounds in the Environment, Masaryk University, Kamenice 753/5, 625 00 Brno, Czech Republic.
Abstract:
Feathers gradually accumulate hormones and reflect long-term average plasma steroid levels during their growth. Feather hormone levels thus provide for the measurement of plasma hormones concentrations integrated over a period of several days or weeks. In this study, we focused on the development of a method to determine testosterone (TEST) and corticosterone (CORT) levels in extracts from feathers of small bodied birds with a limited amount of feathers available per individual. For this purpose, the method had to be verified for a small weight of samples. The present study describes the effect of the conditions of sample preparation and keto-derivatisation on the sensitivity of the LC-ESI-MS/MS analysis of TEST and CORT. Generally, chemical derivatization improves the sensitivity and selectivity of LC-MS/MS analysis. It can be used particularly in situations when the total amount of collected sample is limited (such as in our studies). Both the conditions of feather sample preparation (the selection of the extraction solvent, the time of extraction, and the conditions of solid phase extraction) and the reaction conditions affecting the formation of keto-derivatives (such as reaction temperature and reaction time) were tested. Methanol as the extraction solvent, 8 h as the extraction time, 50 °C as the reaction temperature of derivatization, and 90 min as the reaction time of derivatization are the most suitable conditions in terms of achieving a high sensitivity of analyses. Calibration curves are linear, at least in the range 25-2500 pg mL-1, which is usually found in feather extracts. The limit of detection (LOD) for TEST and CORT was 1.0 and 0.3 pg per mL, respectively. The limit of quantification (LOQ) for TEST and CORT was 3.3 and 1.0 pg per mL, respectively. The optimized procedure was successfully applied for the analysis of TEST and CORT in real feather samples. The method could be used in a variety of research direction including wildlife, agricultural or veterinary studies.
More Related Videos
09:09Semi-Quantitative Analysis of Peptidoglycan by Liquid Chromatography Mass Spectrometry and Bioinformatics
Published on: October 13, 2020
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
Mass Spectrometry: Overview
Tandem Mass Spectrometry
Mass Spectrometry of Amines