Related Experiment Video
Updated: Jan 31, 2026

Isolated Lung Perfusion System in the Rabbit Model
Published on: July 15, 2021
Volumetric but Not Time Capnography Detects Ventilation/Perfusion Mismatch in Injured Rabbit Lung
József Tolnai1, Gergely H Fodor2, Barna Babik3
1Department of Medical Physics and Informatics, University of Szeged, Szeged, Hungary.
Abstract:
Whereas time capnography (Tcap) is routinely displayed during mechanical ventilation, the volumetric representation (Vcap) is seldom used. We compared the diagnostic value of indices derived from Tcap and Vcap following ventilation to perfusion ratio () mismatch subsequent to experimentally induced acute respiratory distress syndrome (ARDS), and alveolar recruitment by elevating the positive end-expiratory pressure (PEEP). Lung injury was induced by iv lipopolysaccharide, whole lung lavage and injurious ventilation in anesthetized, mechanically ventilated rabbits (n = 26). Mainstream Tcap and Vcap were performed to assess normalized phase 2 (Sn2T, Sn2V) and phase 3 slopes (Sn3T, Sn3V) in the time and volumetric domains. Vcap was also used to estimate Enghoff's physiological dead space (VDE). Lung oxygenation index (PaO2/FiO2) and intrapulmonary shunt (Qs/Qt) were derived from arterial and central venous blood gas samples. All measurements were made under baseline conditions, and, following lung injury, under moderate (6 cmH2O) and high PEEP levels (9 cmH2O). Lung injury deteriorated the PaO2/FiO2 (baseline vs. injured 466 ± 10.2 [95% confidence interval] vs. 77.3 ± 17.1 mmHg, p < 0.05) and compromised all mechanical parameters significantly, whereas Tcap parameters exhibited contradictory or inconsistent changes. Conversely, Vcap indices exhibited consistent changes and provided excellent diagnostic value in detecting lung-function deterioration subsequent to lung injury [area under the receiver operating characteristic (ROC) curve of 1.0 ± 0.0, 0.87 ± 0.22 and 0.86 ± 0.22 for VDE, Sn3V and Sn3V/Sn2V, respectively]. Elevated PEEP increased PaO2/FiO2 and decreased Qs/Qt, which was reflected only in the Vcap slope ratio (Sn3V/Sn2V, p < 0.05). Our findings demonstrate the limited value of Tcap to detect ventilation to perfusion ratio () mismatch, following severe lung injury. Conversely, indices derived from Vcap proved to be sensitive for detecting lung volume loss and alveolar recruitment. Therefore, promotion of Vcap is of paramount importance as a real-time, non-invasive, bedside monitoring modality to detect the development of and to follow-up the progression of lung injury in a model of ARDS.
More Related Videos
05:56Author Spotlight: Enhancing Diagnostic Strategies and Biomarker Development for Comprehensive Lung Function Analysis
Published on: August 9, 2024
08:25Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
Related Concept Videos
Mismatch Repair
Mismatch Repair
The Mutator Protein Family Plays a Key Role in DNA Mismatch Repair
The human genome has more than 3 billion base pairs of DNA per cell. Prior to cell division, that vast amount of genetic...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Lung Capacity