Bioelectric Analyses of an Osseointegrated Intelligent Implant Design System for Amputees
Published on: July 15, 2009
Relationship between cortical bone thickness and implant stability at the time of surgery and secondary stability
Kenko Tanaka1,2,3, Irena Sailer2, Ryosuke Iwama1
1Division of Oral and Maxillofacial Surgery, Department of Oral Medicine and Surgery, Tohoku University Graduate School of Dentistry, Sendai, Japan.
Purpose:
It has been suggested that resonance frequency analysis (RFA) can measure changes in the stability of dental implants during osseointegration. This retrospective study aimed to evaluate dental implant stability at the time of surgery (primary stability; PS) and secondary stability (SS) after ossseointegration using RFA, and to investigate the relationship between implant stability and cortical bone thickness.
Methods:
In total, 113 patients who attended the Tohoku University Hospital Dental Implant Center were included in this study. A total of 229 implants were placed in either the mandibular region (n=118) or the maxilla region (n=111), with bone augmentation procedures used in some cases. RFA was performed in 3 directions, and the lowest value was recorded. The preoperative thickness of cortical bone at the site of implant insertion was measured digitally using computed tomography, excluding cases of bone grafts and immediate implant placements.
Results:
The mean implant stability quotient (ISQ) was 69.34±9.43 for PS and 75.99±6.23 for SS. The mandibular group had significantly higher mean ISQ values than the maxillary group for both PS and SS (P<0.01). A significant difference was found in the mean ISQ values for PS between 1-stage and 2-stage surgery (P<0.5). The mean ISQ values in the non-augmentation group were higher than in the augmentation group for both PS and SS (P<0.01). A weak positive correlation was observed between cortical bone thickness and implant stability for both PS and SS in all cases (P<0.01).
Conclusions:
Based on the present study, the ISQ may be affected by implant position site, the use of a bone graft, and cortical bone thickness before implant therapy.
Related Concept Videos
Nuclear Stability
To hold positively charged protons together...
RNA Stability
Stability
The stability of an LTI system is determined by the roots of its characteristic equation, known as poles. A system is stable if it produces a bounded...
BIBO stability of continuous and discrete -time systems
To determine the BIBO stability, the convolution integral is utilized when a bounded continuous-time input is applied to a Linear Time-Invariant (LTI) system....
Combustion Energy: A Measure of Stability in Alkanes and Cycloalkanes
Alkanes undergo combustion in the presence of excess oxygen and high-temperature conditions to give carbon dioxide and water. A combustion reaction is the energy source in natural gas, liquified...
Stability of structures