Related Experiment Video
Updated: Jan 31, 2026

Author Spotlight: Exploring Light-Driven Chemical Reactions and Energy-Harnessing Devices in Photochemical Research
Published on: February 16, 2024
Determination of Secondary Species in Solution through Pump-Selective Transient Absorption Spectroscopy and
M A P Turner1,2, M D Horbury1, V G Stavros1
1Department of Chemistry , University of Warwick , Coventry , CV4 7AL , U.K.
Abstract:
The measured electronic excitations of a given species in solution are often a composite of the electronic excitations of various equilibrium species of that molecule. It is common for a proportion of a species to deprotonate in solution, or form a tautomeric equilibrium, producing new peaks corresponding to the electronic excitations of the new species. One prominent example is alizarin in methanol, which at different temperatures, and in solutions with differing pH, has an isosbestic point between the two dominant excitations at 435 and 540 nm. The peak at 435 nm has been attributed to alizarin; the peak at 540 nm, however, more likely results from a species in equilibrium with alizarin. In this work, we were able to use both experimental and computational techniques to selectively examine electronic properties of both alizarin and its secondary species in equilibrium. This was achieved through use of transient electronic absorption spectroscopy, following selective photoexcitation of a specific species in equilibrium. The resulting transient electronic absorption spectra were compared to the known transient absorption spectra of potential secondary equilibrium species. The ground state absorption spectra associated with each species in equilibrium were predicted using linear-scaling time-dependent density functional theory with an explicitly modeled solvent and compared to the experimental result. This evidence from both techniques combines to suggest that the excitation at 540 nm arises from a specific monoanionic form of alizarin.
More Related Videos
Related Concept Videos
Determining the pH of Salt Solutions
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Molecular Spectroscopy: Absorption and Emission
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...