Published on: April 23, 2021
The Harvard medical practice study trigger system performance in deceased patients.
Dorthe O Klein1, Roger J M W Rennenberg2, Richard P Koopmans2
1Department of Clinical Epidemiology and Medical Technology Assessment (KEMTA), Maastricht University Medical Centre+, Maastricht, the Netherlands. Dorthe.klein@mumc.nl.
This study found that trigger systems for reviewing deceased patients' medical records have suboptimal reproducibility and low specificity, leading to a high false-positive rate and increased costs. Further research is needed for more efficient patient safety systems.
Area of Science:
- Healthcare Quality and Safety
- Medical Record Analysis
- Patient Safety Systems
Background:
- Retrospective chart review using trigger systems is a method to detect adverse events (AEs).
- Deceased patients' records are crucial for identifying AEs and improving care.
- Sampling deceased patients with triggers may enhance performance and reduce review burden.
Purpose of the Study:
- To determine the performance of a trigger system in a sample of deceased patients.
- To calculate the specificity and sensitivity of the trigger system for predicting AEs.
Main Methods:
- Screened 100 randomly selected medical records of deceased patients (2012-2015) using a trigger system.
- Utilized McNemar's test of symmetry, observed agreement, Cohen's Kappa, and PABAK for statistical analysis.
- Evaluated trigger performance for any trigger present and for individual triggers.
Main Results:
- Observed agreement for any trigger was 75% (Kappa: 0.5, PABAK: 0.5).
- Individual trigger agreement averaged 90% (Kappa: 0.42, PABAK: 0.8).
- Recalculated specificity was 58% and sensitivity was 92%; two AEs were found in cases without prior triggers.
Conclusions:
- The reproducibility of trigger systems is suboptimal, with performance varying among individual triggers.
- Low specificity results in a high false-positive rate, increasing the cost of labor-intensive record reviews.
- Development of more effective and efficient patient safety systems is necessary.
Related Concept Videos
Inhaled Medications
Bioavailability Study Design: Healthy Subjects Versus Patients
Characteristics of Practical Op Amps
The ratio of differential gain to the common-mode gain is defined as the common-mode rejection ratio (CMRR). This ratio quantifies the ability of operational amplifiers (op-amps) to reject common-mode...
Theoretical Foundations of Nursing Practice
Theories provide a perspective to assess patients' conditions and organize data and methods. They also assist in analyzing and interpreting information. They represent a...
Equivalent Circuits for Practical Transformers
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
Endocarditis III: Medical Management