Related Experiment Video
Updated: Jan 31, 2026

Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Evaluating the effect of nasal septoplasty on atrial electromechanical features
Osman Kayapinar1, Adnan Kaya1, Cem Ozde1
1Cardiology, Duzce University Medical School, 81100 Duzce, Turkey.
Background:
Recent studies have demonstrated that right ventricular (RV) dysfunction and increased pulmonary artery pressure may be frequent in patients with upper airway obstruction. In this study, we evaluated atrial conduction delays in patients with upper airway obstruction secondary to nasal septum deviation (NSD).
Methods:
A total of 32 patients with upper airway obstruction secondary to NSD undergoing a septoplasty procedure were enrolled in this study. Preoperative electrocardiography and transthoracic echocardiography were performed in all patients who underwent surgery. The mean pulmonary artery pressure (mPAP) and atrial conduction time (ACT) were recorded before and 6 months after the surgical procedures.
Results:
The PAP was significantly lower postoperatively than preoperatively (20.75 ± 4.83 vs. 24.68 ± 5.26; P < 0.001). The postoperative Electromechanical Delay of Mitral septal wall (EMD-MS) value was significantly lower than that preoperatively (46.20 ± 8.5 vs. 40.5 ± 9.9; P < 0.001). The postoperative Electromechanical Delay of Mitral lateral wall (EMD-ML) value decreased significantly compared to the preoperative period (46.3 ± 7.4 vs. 40.6 ± 9.3; P < 0.001). The postoperative Electromechanical Delay of Tricuspit lateral wall (EMD-TL) value was significantly lower than that preoperatively (43.8 ± 7.0 vs. 38.1 ± 9.1; P < 0.001). There was no significant change in pre- or postoperative measurements of inter- and intra-atrial conduction delays.
Conclusions:
We demonstrated that upper airway obstruction secondary to NSD causes a significant increase in mPAP and a significant delay in ACT, which improved after nasal septoplasty. According to these results, we conclude that upper airway obstruction may be an important risk factor for pulmonary arterial hypertension, RV dysfunction, and atrial arrhythmias, especially in unoperated cases.
Related Concept Videos
Irritable Bowel Syndrome II: Clinical Features and Diagnostic Evaluation
Irritable Bowel Syndrome (IBS) is classified into subtypes based on the predominant bowel habits as determined by the Bristol Stool Form Scale (BSFS). The subtypes are:
Nose and Nasal Cavity
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
COPD: Pathogenesis and Clinical Features
The primary cause for the onset of COPD is cigarette smoking and exposure to air pollution. These hazardous factors initiate a chain reaction within the lungs, resulting in chronic inflammation, damage to the airways, and a...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Special Features of Adaptive Immunity
The primary cell types involved in adaptive immunity are T cells and B cells. Each type has a unique role in defending the body against pathogens. T cells are responsible for cell-mediated immunity. They identify and eliminate infected cells directly,...