Comparison of Automated Office Blood Pressure With Office and Out-Off-Office Measurement Techniques
Marco Pappaccogli1, Silvia Di Monaco1, Elisa Perlo1
1From the Hypertension Unit, Division of Internal Medicine, Department of Medical Sciences (M.P., S.D.M., E.P., J.B., S.M., F.R., F.V.), University of Turin, Italy.
Abstract:
Automated office blood pressure (AOBP) has emerged as a valuable tool to assess patient's BP status, but the lack of strong evidence to establish a threshold value for hypertension diagnosis limits its use in clinical practice. We aimed at synthesizing the published literature through a meta-analysis of studies comparing AOBP with other BP measurement techniques and at analyzing the differences between AOBP and physician's office BP, nonphysician's office BP, daytime ambulatory BP monitoring, and home BP monitoring. We searched PubMed database for articles published up to April 2018; eligible studies compared AOBP with office and out-of-office measurement techniques and reported the BP differences or BP values obtained. Twenty-six studies, for a total of 7116 patients, were included in the analysis. AOBP values were lower than physician (systolic BP, -10.48 mm Hg; 95% CI, -13.15 to -7.81/diastolic BP, -4.44 mm Hg; 95% CI, -6.07 to -2.80) and nonphysician office ones (systolic BP, -6.89 mm Hg; 95% CI, -8.75 to -5.04/diastolic BP -3.82 mm Hg; 95% CI, -4.86 to -2.78). No significant differences were found between AOBP and daytime ambulatory BP monitoring (systolic BP, -1.85; 95% CI, -4.50 to 0.79/diastolic BP, 0.12; 95% CI, -1.42 to 1.66) and home BP monitoring (systolic BP, -2.65; 95% CI, -8.42 to 3.12/diastolic BP, -1.67; 95% CI, -4.20 to 0.87). AOBP readings did not differ significantly from out-of-office blood pressure, still remaining an office technique; it may improve hypertension diagnosis by overcoming some of office BP limitations, including the white coat effect.
Related Concept Videos
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the...
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer