Comparison of invasive and non-invasive aortic wave intensity and wave power analyses in sheep
Remi Kowalski1,2,3, Jonathan P Mynard1,3,4, Joseph J Smolich1,3
1Murdoch Children's Research Institute, University of Melbourne, Melbourne, Australia.
Objective:
Wave intensity (WI) and wave power (WP) analyses are powerful approaches for assessing ventricular-vascular interactions and arterial dynamics using invasive and non-invasive methods. However, in vivo comparison of these methods for large arteries is lacking. This study assessed agreement, correlation and relative changes in wave size in invasive and non-invasive aortic WI/WP analyses, and associated sources of error.
Approach:
The proximal descending thoracic aorta (DTA) of nine wethers was instrumented with a micromanometer and perivascular transit-time flow probe to measure high-fidelity blood pressure (P) and flow (Q) for invasive WI/WP analyses at baseline and during haemodynamic perturbations produced by cardiac pacing, distal DTA constriction and dobutamine-induced inotropic stimulation. In 212 experimental runs, concurrent echocardiographic DTA diameter and velocity (U) data were acquired for non-invasive WI/WP analyses, with measurement of forward compression wave (FCW), backward compression wave (BCW) and forward decompression wave (FDW) cumulative intensity (CI), cumulative power (CP) and wave-related pressure changes (ΔP).
Main Results:
Although agreement between invasive and non-invasive FCW, BCW and FDW CI/CP measures was variable (bias -84% to +7%), correlation was good (R = 0.66-0.84), with lower bias and higher correlation for ΔP variables and similar relative changes in FCW and BCW CI/ΔP during haemodynamic perturbations. Main error sources were overestimation of invasive U due to assumed fixed vessel diameter, inaccuracies in non-invasive Q, and non-invasive underestimation of peak P/U and Q rates of change.
Significance:
Despite variable agreement, non-invasive CI/CP indices correlate well with invasive measurements, and detect relative changes in major waves induced by haemodynamic perturbations.
More Related Videos
06:51Author Spotlight: Development of a Minimally Invasive Large-Animal Model for Reliable and Reproducible Cardiovascular Research
Published on: October 20, 2023
06:09Low-intensity Blast Wave Model for Preclinical Assessment of Closed-head Mild Traumatic Brain Injury in Rodents
Published on: November 6, 2020
Related Concept Videos
Intensity Of Electromagnetic Waves
Energy and Power of a Wave
Waves can also be concentrated or spread out, as characterized by the intensity of the wave. Intensity is directly...
Intensity and Pressure of Sound Waves
Unlike the time average of a sinusoidal term, which is zero since it is positive...
The Wave Nature of Light
Wave Parameters
Reflection of Waves