Related Experiment Video
Updated: Jan 31, 2026

Highly Sensitive and Rapid Fluorescence Detection with a Portable FRET Analyzer
Published on: October 1, 2016
A new quinoline-derived highly-sensitive fluorescent probe for the detection of hydrazine with excellent
Qingqing Wu1, Jianlu Zheng2, Wencui Zhang2
1College of Materials Science and Engineering, Shenzhen Key Laboratory of Polymer Science and Technology, Guangdong Research Center for Interfacial Engineering of Functional Materials, Nanshan District Key Lab for Biopolymers and Safety Evaluation, Shenzhen University, Shenzhen 518060, PR China; Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, PR China.
Abstract:
Hydrazine is an important industrial material yet highly toxic and extremely harmful to people's health when over-exposed in the environment, thus monitoring hydrazine is of great significance. In this work, a novel highly fluorescent fluorophore BQ-OH, based on hydroxyl- and benzo[d]oxazole-substituted quinoline structure, was synthesized and esterified with 4-biomobutyric acid to afford a fluorescent probe BQABr for the selective detection of hydrazine. The probe follows SN2(nucleophilic substitution)-cyclization sensing mechanism with remarkable response, excellent sensitivity and selectivity. Spectra experiments in aqueous solutions demonstrated that BQABr exhibited an excellent ratiometric fluorescence response toward hydrazine with two well separated emission bands before/after sensing reaction. Emission peak shifted over 130 nm from 387 nm to 521 nm, and unexpectedly outstanding ratio signal enhancement over 3000-fold was achieved. Due to the large spectra response, a very low detection limit of 5.8 nM (0.19 ppb) was obtained. Selectivity experiment was performed, showing BQABr had nearly no spectra response to other possible disturbing analytes. The probe-coated test papers were fabricated and successfully applied to detect gaseous hydrazine. Furthermore, potential application for the detection of hydrazine in both environmental samples and biological samples (living cells) has been demonstrated.
Related Concept Videos
Atomic Spectroscopy: Absorption, Emission, and Fluorescence
Microsoft Excel: Plotting Mean, SD, and SE
First, calculate the mean, SD, and SE of your data. The mean is obtained using the formula `=AVERAGE(range)`, while SD can be calculated with `=STDEV.P(range)` for a population or `=STDEV.S(range)` for a sample. SE is calculated as `=SD/SQRT(n)`, where `n` is the sample size.
To plot these values, use a bar...
Emission Spectra
Microsoft Excel: Student's t-Test
To conduct a t-test in Excel, use the T.TEST function or the "Data...
Microsoft Excel: Pearson's Correlation
Microsoft Excel: Regression Analysis
To perform regression...

