Related Experiment Video
Updated: Jan 31, 2026

Analysis of Cell Suspensions Isolated from Solid Tissues by Spectral Flow Cytometry
Published on: May 5, 2017
Correlation-and-Spectral Analysis of Time Series for Microcirculatory Parameters in Vessels of Symmetrical Organs
L V Mezentseva1, S S Pertsov2,3
1P. K. Anokhin Research Institute of Normal Physiology, Moscow, Russia. l.v.mezentseva@mail.ru.
Abstract:
The correlation relationships between microcirculatory parameters were studied in vessels of symmetrical organs in humans. Parameters of microcirculation in healthy volunteers were measured by the method of laser Doppler flowmetry (LDF). LDF-signal transducers were placed symmetrically on the lower parts of the right and left shoulders (3 cm above the elbow bend). Correlations between various components of the amplitude-frequency spectrum for blood flow fluctuations (myogenic, neurogenic, respiratory, and cardiac) were evaluated on symmetrical sides. A significant correlation was found for the mean value of vascular perfusion on the right side with the neurogenic, myogenic, respiratory, and cardiac components on the same side. However, the mean value of vascular perfusion on the light side was interrelated only with the cardiac component. A positive correlation was revealed between the neurogenic and myogenic components on the left side. However, the neurogenic component on the right side was positively related to the myogenic component on the opposite side. Asymmetry of correlation relationships was also observed for the respiratory and cardiac components of study spectrum. Our results illustrate the specific regulation of microcirculatory blood flow in paired organs, which is associated with the existence of functional asymmetry. The physiological mechanisms for this asymmetry require further experimental and clinical studies.
More Related Videos
07:11ARL Spectral Fitting as an Application to Augment Spectral Data via Franck-Condon Lineshape Analysis and Color Analysis
Published on: August 19, 2021
06:35Construction and Systematical Symmetric Studies of a Series of Supramolecular Clusters with Binary or Ternary Ammonium Triphenylacetates
Published on: February 15, 2016
Related Concept Videos
Time-Series Graph
Discrete-Time Fourier Series
For a discrete-time periodic signal x[n]...
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the...
Correlations
Symmetric Member in Bending
Noncompartmental Analysis: Miscellaneous Pharmacokinetic Parameters
One key aspect of the noncompartmental approach is determining a drug's total clearance. This can be done by dividing the drug dose by the area under the concentration-time curve from zero to infinity. The area under the concentration-time curve represents the drug's...