Simulation of photon-counting detectors for conversion of dual-energy-subtracted computed tomography number to
1Department of Radiological Technology, School of Health Sciences, Faculty of Medicine, Niigata University, Niigata, 951-8518, Japan. masaito@clg.niigata-u.ac.jp.
Abstract:
For accurate tissue-inhomogeneity correction in radiotherapy treatment planning, the author previously proposed a conversion of the energy-subtracted computed tomography (CT) number to electron density (ΔHU-ρe conversion). The purpose of the present study was to provide a method for investigating the accuracy of a photon-counting detector (PCD) used in the ΔHU-ρe conversion by performing dual-energy CT image simulations of a PCD system with two energy bins. To optimize the tube voltage and threshold energy, the image noise and errors in ρe calibration were evaluated using three types of virtual phantoms: a 35-cm-diameter pure water phantom, 33-cm-diameter solid water surrogate phantom equipped with 16 inserts, and another solid water surrogate phantom with a 25-cm diameter. The third phantom was used to investigate the effect of the object's size on the ρe-calibration accuracy of PCDs. Two different scenarios for the PCD energy response were considered, corresponding to the ideal and realistic cases. In addition, a simple correction method for improving the spectral separation of the dual energies in a realistic PCD was proposed to compensate for its performance loss. In the realistic PCD case, there exists a trade-off between the image noise and ρe-calibration errors. Furthermore, the weakest image noise was nearly twice that for the ideal case, and the ρe-calibration error did not reach practical levels for any threshold energy. Nevertheless, the proposed correction method is likely to decrease the ρe-calibration errors of a realistic PCD to the level of the ideal case, yielding more accurate ρe values that are less affected by object size variation.
More Related Videos
07:00Preparing Lamellae from Vitreous Biological Samples Using a Dual-Beam Scanning Electron Microscope for Cryo-Electron Tomography
Published on: August 5, 2021
12:24Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
Published on: July 17, 2012
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Strain-Energy Density
In the elastic region of a material, the relationship between the stress and the strain is linear and follows Hooke's Law. The strain energy density in this region...
Imaging Studies III: Computed Tomography
Gene Conversion
The Energies of Atomic Orbitals
Free Energy