Related Experiment Video
Updated: Jan 31, 2026

Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential
Published on: May 25, 2020
Comparison of defect depths for sinusoidal and circular perimetric stimuli in patients with glaucoma
William H Swanson1, Brett J King1
1Indiana University School of Optometry, Bloomington, USA.
Purpose:
Clinical use of perimetric testing in patients with glaucoma typically assumes that perimetric defects will be less deep for larger than smaller stimuli. However, studies have shown that very large sinusoidal stimuli can yield similar defects as small circular stimuli. In order to provide guidelines for new perimetric stimuli, we tested patients with glaucoma using five different stimuli and compared defects to their patterns of retinal nerve fibre layer (RNFL) damage.
Methods:
Twenty subjects with glaucoma were imaged with optical coherence tomography (OCT) volume scans to allow for en face RNFL images and were also tested on a custom perimetry station with five stimuli: Goldmann sizes III and V, a two-dimensional Gaussian blob (standard deviation 0.5°) and a 0.5 cycle degree-1 sinusoidal grating presented two ways: flickered at 5 Hz, and pulsed for 200 ms instead of flickered. En face RNFL images were reviewed with the visual field locations overlaid, and each location was labelled for a patient as either no visible RNFL defect or as wedge, slit, edge, or diffuse defect. Nineteen age-similar controls were tested with the same stimuli to define depth of defect as difference from mean normal. Bland-Altman analysis was used to test three predictions of neural modelling by making five comparisons.
Results:
Bland-Altman analysis confirmed the three predictions. The flickered sinusoid gave deeper defects in damaged areas than the pulsed sinusoid (r = 0.25, p < 0.0001). When comparing data for sizes III and V there was increased spread of the data in deeper defects in the direction of size III having deeper defect (r = 0.35, p < 0.0001). The size V stimulus yielded shallower defects than a stimulus of similar size but with blurred edges (r = 0.20, p = 0.0004).
Conclusions:
On average, all stimuli produced similar results comparing across type of RNFL damage. However, there were systematic patterns consistent with predictions of neural modelling: in damaged areas, depth of defect tended to be greater for the flickered sinusoid than the pulsed sinusoid, greater for the size III stimulus than the size V stimulus, and greater for the Gaussian blob than for the size V stimulus.
Related Concept Videos
Sinusoidal Sources
In homes, the power supplies use sinusoidal sources to provide electricity. These sources generate a voltage that varies sinusoidally...
Exponential and Sinusoidal Signals
Glaucoma: Overview
Graphical and Analytic Representation of Sinusoids
The first step is measuring the peak-to-peak value, which is twice the amplitude of the sinusoid. This provides information about the maximum voltage swing of the waveform.
Secondly, the period and angular frequency are determined. The period is the time taken for one complete cycle of the waveform, while...
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
The Sense of Self: Reflected Self-Appraisal and Social Comparison

