Related Experiment Video
Updated: Jan 30, 2026

Establishment and Validation of a Rat Model of Pulmonary Arterial Hypertension Associated with Pulmonary Fibrosis
Published on: May 23, 2025
Use of a right ventricular continuous flow pump to validate the distensible model of the pulmonary vasculature
F Vanden Eynden1, P Segers, T Bové
1Department of Cardiac Surgery, Université Libre de Bruxelles, Hopital Académique, Erasme, Brussels, Belgium. frederic.vanden.eynden@erasme.ulb.ac.be.
Abstract:
In the pulmonary circulation, resistive and compliant properties overlap in the same vessels. Resistance varies nonlinearly with pressure and flow; this relationship is driven by the elastic properties of the vessels. Linehan et al. correlated the mean pulmonary arterial pressure and mean flow with resistance using an original equation incorporating the distensibility of the pulmonary arteries. The goal of this study was to validate this equation in an in vivo porcine model. In vivo measurements were acquired in 6 pigs. The distensibility coefficient (DC) was measured by placing piezo-electric crystals around the pulmonary artery (PA). In addition to experiments under pulsatile conditions, a right ventricular (RV) bypass system was used to induce a continuous pulmonary flow state. The Linehan et al. equation was then used to predict the pressure from the flow under continuous flow conditions. The diameter-derived DC was 2.4%/mmHg (+/-0.4%), whereas the surface area-based DC was 4.1 %/mmHg (+/-0.1%). An increase in continuous flow was associated with a constant decrease in resistance, which correlated with the diameter-based DC (r=-0.8407, p=0.044) and the surface area-based DC (r=-0.8986, p=0.028). In contrast to the Linehan et al. equation, our results showed constant or even decreasing pressure as flow increased. Using a model of continuous pulmonary flow induced by an RV assist system, pulmonary pressure could not be predicted based on the flow using the Linehan et al. equation. Measurements of distensibility based on the diameter of the PA were inversely correlated with the resistance.
More Related Videos
Related Concept Videos
Reliability and Validity
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
Pumped Concrete
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...
Refrigerators and Heat Pumps
A household refrigerator removes heat from...
Data Validation
Key parameters for method validation include:

