Related Experiment Video
Updated: Jan 30, 2026

Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
Characterization of functionally significant coronary artery disease by a coronary computed tomography
Constantinos D Anagnostopoulos1, Panagiotis K Siogkas2,3, Riccardo Liga4
1Biomedical Research Foundation of Academy of Athens, 4 Soranou Ephesiou, Athens, Greece.
Aims:
To test the hypothesis that virtual functional assessment index (vFAI) is related with regional flow parameters derived by quantitative positron emission tomography (PET) and can be used to assess abnormal vasodilating capability in coronary vessels with stenotic lesions at coronary computed tomography angiography (CCTA).
Methods And Results:
vFAI, stress myocardial blood flow (MBF), and myocardial flow reserve (MFR) were assessed in 78 patients (mean age 62.2 ± 7.7 years) with intermediate pre-test likelihood of coronary artery disease (CAD). Coronary stenoses ≥50% were considered angiographically significant. PET was considered positive for significant CAD, when more than one contiguous segments showed stress MBF ≤2.3 mL/g/min for 15O-water or <1.79 mL/g/min for 13N-ammonia. MFR thresholds were ≤2.5 and ≤2.0, respectively. vFAI was lower in vessels with abnormal stress MBF (0.76 ± 0.10 vs. 0.89 ± 0.07, P < 0.001) or MFR (0.80 ± 0.10 vs. 0.89 ± 0.07, P < 0.001). vFAI had an accuracy of 78.6% and 75% in unmasking abnormal stress MBF and MFR in 15O-water and 82.7% and 71.2% in 13N-ammonia studies, respectively. Addition of vFAI to anatomical CCTA data increased the ability for predicting abnormal stress MBF and MFR in 15O-water studies [AUCccta + vfai = 0.866, 95% confidence interval (CI) 0.783-0.949; P = 0.013 and AUCccta + vfai = 0.737, 95% CI 0.648-0.825; P = 0.007, respectively]. An incremental value was also demonstrated for prediction of stress MBF (AUCccta + vfai = 0.887, 95% CI 0.799-0.974; P = 0.001) in 13N-ammonia studies. A similar trend was recorded for MFR (AUCccta + vfai = 0.780, 95% CI 0.632-0.929; P = 0.13).
Conclusion:
vFAI identifies accurately the presence of impaired vasodilating capability. In combination with anatomical data, vFAI enhances the diagnostic performance of CCTA.
More Related Videos
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Coronary Artery Disease I: Introduction
Coronary Artery Disease II: Pathophysiology
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Coronary Artery Disease V: Interprofessional Care
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...