A decoupled circuital model methodology for calculating DC currents in AC grids induced by HVDC grounding current

Lingyu Zhu1, Chenzhao Fu2, Hao Liu3

  • 1Xi'an Jiaotong University, Xi'an, Shaanxi, China.

Plos One
|January 11, 2019
PubMed

Related Concept Videos

Current Growth And Decay In RL Circuits01:30

Current Growth And Decay In RL Circuits

The current growth and decay in RL circuits can be understood by considering a series RL circuit consisting of a resistor, an inductor, a constant source of emf, and two switches. When the first switch is closed, the circuit is equivalent to a single-loop circuit consisting of a resistor and an inductor connected to a source of emf. In this case, the source of emf produces a current in the circuit. If there were no self-inductance in the circuit, the current would rise immediately to a steady...
4.6K
Fast Decoupled and DC Powerflow01:24

Fast Decoupled and DC Powerflow

The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
752
Resistor in an AC Circuit01:31

Resistor in an AC Circuit

An alternating emf or voltage source is needed to supply an alternating current (AC) to a circuit. A coil of wire rotating in a magnetic field at a constant angular speed represents such a source. It also generates a sinusoidal alternating emf and serves as an industrial alternator.
One-way current through the meter is measured using diodes. A diode is a device with better conductivity in one direction compared to the other; in its ideal state, it has zero resistance in one direction and allows...
3.2K
Power in an AC Circuit01:26

Power in an AC Circuit

In a DC circuit, the power consumed is simply the product of the DC voltage times the DC current, given in watts. However, the power consumed for AC circuits with reactive components is calculated differently. Since electrical power is the "rate" at which energy is used in a circuit, all electrical and electronic components and devices have a safe operating range for electrical power.
In a DC circuit, there is no sinusoidal waveform associated with the supply; the voltages and currents are...
2.3K
Electrical Current01:10

Electrical Current

Electrical current is defined as the rate at which charge flows. When there is a large current present, such as that used to run a refrigerator, a large amount of charge moves through the wire in a small amount of time. If the current is small, such as that used to operate a handheld calculator, a small amount of charge moves through the circuit over a long period of time. The SI unit for current is the ampere (A), named for the French physicist André-Marie Ampère (1775–1836).
7.2K
RMS Value in AC Circuit01:13

RMS Value in AC Circuit

The root mean square (RMS) value is a measure of the effective or average value of an alternating current (AC) waveform. In AC circuits, the voltage or current waveform constantly changes direction and magnitude, making it difficult to describe with a single value. The RMS value provides a convenient way to calculate the equivalent DC voltage or current that would produce the same heating effect in a resistor as the AC waveform.
Mathematically, the RMS value of an AC waveform is the square root...