Related Experiment Video
Updated: Jan 30, 2026

Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
Intra-arterial pulse wave analysis during thrombectomy for the assessment of collateral status - A feasibility study
Johanna Sandmann1, Thorsten Sichtermann1, Franziska Sonja Müschenich1
1Department of Diagnostic and Interventional Neuroradiology, University Hospital, RWTH Aachen University, Aachen, Germany.
Purpose:
Knowledge of the collateralization of an occluded vessel is important for the risk-benefit analysis of difficult revascularization maneuvers during mechanical thrombectomy. If the territory behind a clot is well perfused, one could desist from performing a risky thrombectomy maneuver. The arterial pulse pressure curve may serve as an indicator for the collateralization of an occluded target vessel. We investigated the feasibility of arterial pulse measurements with a standard microcatheter.
Methods:
We measured the intra-arterial blood pressure proximal and distal to the clot in 40 thrombectomy maneuvers in a porcine stroke model. We used a microcatheter (Trevo Pro 18, Stryker, Kalamazoo, CA, USA), a pressure transducer (MEMSCAP SP844), an AdInstruments Powerlab 16/35 workstation, and LabChart 8 Software (AdInstruments, Dunedin, New Zealand).
Results:
Median arterial blood pressure proximal and distal to the clot was 96.0 mmHg (IQR, 23.8 mmHg) and 47.5 mmHg (IQR, 43.5 mmHg), respectively (p < .001). The median difference between systolic maximum and diastolic minimum proximal and distal to the clot decreased significantly from 1.8 mmHg (IQR, 3.6 mmHg) to 0.0 mmHg (IQR, 0.5 mmHg) (p < .001). There was loss of the curve in 26 of 40 cases and loss of pressure in 23 of 40 cases (p = .008). There was no significant correlation between vessel diameter and either loss of the pulse pressure curve (p = .20) or overall pressure loss (p = .31).
Conclusion:
It is possible to measure the pulse pressure proximal and distal to the clot with a standard microcatheter used during mechanical thrombectomy.
Related Concept Videos
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Pulse Assessment Sites
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Pulse
The pulse serves as a clinical...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...

