Related Experiment Video
Updated: Jan 30, 2026

Drug-Induced Sleep Endoscopy DISE with Target Controlled Infusion TCI and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
Skeletal changes after rapid maxillary expansion in children with obstructive sleep apnea evaluated by low-dose
Paola Pirelli1, Ezio Fanucci2, Aldo Giancotti1
1Department of Clinical Sciences and Translational Medicine, University Tor Vergata, Rome, Italy.
Objective:
The objective of this study was to evaluate the skeletal effects of rapid maxillary expansion (RME) therapy performed using teeth as anchors, in obstructive sleep apnea (OSA) children, by low-dose computed tomography (CT) of the midpalatal suture opening, maxillary base width, nasal cavities width, first molar angulation and, unlike most studies in the literature, on the pterygoid processes distance.
Methods:
Fourteen children (mean age 8.68 years) with OSA presenting a malocclusion characterized by upper-jaw contraction had 16-Multislice CT (MSCT) scans taken before (T0) and after (T1) RME. All exams were performed using a rigid protocol to ensure reproducibility of image collection over time, with a 16-row MSCT scanner equipped with a Dentascan reconstruction program. Scanning parameters were as follows: scout view in the anteroposterior (AP) and laterolateral (LL); 1.25-mm slice thickness with 0.6-mm collimation from the dentoalveolar and basal areas of the maxilla up to the nasal cavity, parallel to the palatal plane; 80 kV, 100 mA with an 11.25-mm table speed/rotation, rotation time 0.6 s. Matrix size was 512 × 512.
Results:
Opening of the midpalatal suture was demonstrated in all cases. The results showed statistically significant T0 to T1 increments in all treated cases and clear imaging findings.
Conclusion:
Use of three-dimensional (3D)-CT for follow-up studies requires a very rigid protocol to maintain reproducible positions in the scanner over time. The images confirm the real remodeling of craniofacial structure. However, to be valid such an imaging approach needs great attention to reproducibility of anatomic images over time. The changes in volume of the UA, even with a rigid protocol, cannot be affirmed with 3D-CT. There is a need to improve the definition of markers using this imaging approach when performing longitudinal studies; currently this issue is unresolved.
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Drug Dosing: Infants and Children
Imaging Studies III: Computed Tomography
Classification of Skeletal Muscle Fibers
Slow-Twitch Muscle Fibers
Slow oxidative, muscle fibers appear red due to large numbers of capillaries and high levels of...
Insufficient Sleep and Sleep Deprivation
Sleep deprivation is a more severe form of sleep loss...

