Report of Three Cases of AKI Following Weight-Based Gentamicin Prophylaxis for IPP Implantation: Potential Concerns

Robert H Moore1, Uzoma A Anele2,3, Sarah C Krzastek2,3

  • 1Virginia Commonwealth University School of Medicine, 1201 E. Marshall Street, Richmond, VA 23298, USA.

Case Reports in Urology
|January 12, 2019
PubMed

Insights

Single high-dose gentamicin prophylaxis, recommended for urologic procedures, may pose a risk of acute kidney injury in patients undergoing penile prosthesis surgery, despite theoretical renal safety. Further evidence-based studies are needed to confirm this risk.

Area of Science:

  • Nephrology
  • Urology
  • Pharmacology

Background:

  • The American Urological Association guidelines (2008) recommend single high-dose (5 mg/kg) weight-based gentamicin prophylaxis for procedures involving urologic prostheses.
  • This recommendation is based on theoretical renal safety and enhanced antimicrobial efficacy of a single large dose.
  • The specific risk of gentamicin-induced nephrotoxicity in penile prosthesis surgery remains unquantified by evidence-based studies.

Observation:

  • This study presents three cases of postoperative acute kidney injury (AKI).
  • These cases occurred in patients who received weight-based gentamicin prophylaxis prior to inflatable penile prosthesis implantation.
  • The patient population for penile prostheses often has high rates of pre-existing comorbidities.

Findings:

  • Weight-based gentamicin prophylaxis may be associated with a risk of acute kidney injury following penile prosthesis implantation.
  • The theoretical renal safety of high-dose gentamicin in this specific surgical context requires further investigation.
  • Postoperative AKI can be a serious complication, particularly in patients with comorbidities.

Implications:

  • Clinical practice guidelines for gentamicin prophylaxis in penile prosthesis surgery may need re-evaluation.
  • Evidence-based studies are crucial to establish the true nephrotoxic risk of gentamicin in this patient cohort.
  • Identifying and mitigating risks associated with perioperative antibiotic prophylaxis is essential for patient safety.

Related Concept Videos

Data Reporting and Recording01:24

Data Reporting and Recording

Reporting and recording are crucial in data documentation. The timely, thorough, and accurate documentation of facts is essential when recording patient data. Failure to record findings during an assessment or interpretation of a problem will result in loss of information and make the patient document unreliable. The reader is left with general impressions if the information is not specific. A recording is documenting data of the individual's health information in a traceable, secure, and...
5.4K
Weighted Mean00:57

Weighted Mean

While taking the arithmetic, geometric, or harmonic mean of a sample data set, equal importance is assigned to all the data points. However, all the values may not always be equally important in some data sets. An intrinsic bias might make it more important to give more weightage to specific values over others.
For example, consider the number of goals scored in the matches of a tournament. While computing the average number of goals scored in the tournament, it may be more important to...
6.3K
Atomic Weight01:25

Atomic Weight

Protons and neutrons have approximately the same mass, about 1.67 × 10-24 grams. Scientists arbitrarily define this amount of mass as one atomic mass unit (amu) or one Dalton. Electrons are much smaller in mass than protons, weighing only 9.11 × 10-28 grams, or about 1/1800 of an atomic mass unit. As a result, they do not contribute much to an element's overall atomic mass. This means that, when considering atomic mass, it is customary to ignore the mass of any electrons and...
12.7K
Mass and Weight01:19

Mass and Weight

Mass and weight are often used interchangeably in everyday conversation. For example,  medical records often show our weight in kilograms, but never in the correct units of newtons. In physics, however, there is an important distinction. Weight is the pull of the Earth on an object. It depends on the distance from the center of the Earth. Weight dramatically varies if we leave the Earth's surface, unlike mass, which does not vary with location. On the Moon, for example, the...
15.3K
Apparent Weight01:09

Apparent Weight

True weight is the measure of the gravitational force acting on an object. However, if the object accelerates, its measured weight is different from its true weight. Similar observations can be made when the object is submerged in water. An object's weight in water is its apparent weight, which is equal to the difference between its true weight and the buoyant forces.
Consider a person standing on a bathroom scale inside an elevator. If the scale is accurate at rest, its reading equals the...
9.8K
Standard Electrode Potentials03:02

Standard Electrode Potentials

On comparing the reactivity of silver and lead, it is observed that the two ionic species, Ag+ (aq) and Pb2+ (aq), show a difference in their redox reactivity towards copper: the silver ion undergoes spontaneous reduction, while the lead ion does not. This relative redox activity can be easily quantified in electrochemical cells by a property called cell potential. This property is commonly known as cell voltage in electrochemistry, and it is a measure of the energy which accompanies the charge...
50.3K