Related Experiment Video
Updated: Jan 30, 2026

Electrochemical Impedance Spectroscopy as a Tool for Electrochemical Rate Constant Estimation
Published on: October 10, 2018
Electrochemically Controlled RAFT Polymerization for Highly Sensitive Electrochemical Biosensing of Protein Kinase
Qiong Hu1,2,3, Jinming Kong1, Dongxue Han2,3
1School of Environmental and Biological Engineering , Nanjing University of Science and Technology , Nanjing 210094 , P. R. China.
Abstract:
Phosphorylation of proteins catalyzed by protein kinases (PKs) is essential to many biological processes; the sensitive detection of PK activity and the screening of PK inhibitors are thus integral to disease diagnosis and drug discovery. Herein, a highly sensitive biosensor has been fabricated for the electrochemical detection of PK activity by exploiting the electrochemically controlled reversible addition-fragmentation chain transfer (eRAFT) polymerization as a novel amplification strategy. The fabrication of the eRAFT-polymerization-based electrochemical biosensor involves (1) the immobilization of substrate peptides onto a gold electrode by way of gold-sulfur self-assembly, (2) the site-specific phosphorylation of substrate peptides by PKs, (3) the anchoring of carboxyl-group-containing chain transfer agents (CTAs) to the phosphorylated sites, and (4) the eRAFT polymerization under a potentiostatic condition, using ferrocenylmethyl methacrylate (FcMMA) as the monomer. Through the eRAFT polymerization, long polymer chains containing numerous electroactive Fc tags can be de novo grafted from each phosphorylated site, resulting in significant amplification of the electrochemical detection signal. The as-fabricated biosensor is highly selective and features a very low detection limit of 1.02 mU mL-1, in the presence of adenosine 3',5'-cyclic monophosphate (cAMP)-dependent PK (PKA) as the model target. Results also demonstrate that it can be applied to the screening of PK inhibitors and the detection of PK activity in complex serum samples and cell lysates. Moreover, it holds the merits of easy fabrication, high efficiency, and low cost, which make it a promising tool for the detection of PK activity and the screening of potential PK inhibitors.
More Related Videos
10:44Translating Extracellular Electron Transfer Activities with Organic Electrochemical Transistors
Published on: January 31, 2025
08:31Probing Surface Electrochemical Activity of Nanomaterials using a Hybrid Atomic Force Microscope-Scanning Electrochemical Microscope AFM-SECM
Published on: February 10, 2021
Related Concept Videos
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Electrochemical Gradient and Channel Proteins: An Overview
The electrical gradient: The electrical gradient across cell membranes refers to the difference in electric charge between the inside and outside of a cell. This difference drives the movement of ions towards or away from the cells. For instance, if the inside of the cell is more negatively charged relative to...
Protein Kinases and Phosphatases
Protein kinases
Many proteins in the cell are regulated by phosphorylation, the addition of a phosphate group. A family of enzymes called kinases...
Protein Kinases and Phosphatases
Interfacial Electrochemical Methods: Overview
Secondary Active Transport