Related Experiment Video
Updated: Jan 30, 2026

Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
Interobserver Variability in Applying American Society of Echocardiography/European Association of Cardiovascular
Sherif F Nagueh1, Theodore P Abraham2,3, Gerard P Aurigemma
1Methodist DeBakey Heart and Vascular Center, Center for Outcomes Research, Houston Methodist Research Institute, TX (S.F.N., M.A.C.-p., K.C.E.t., J.X.).
Background:
Assessment of left ventricular (LV) filling pressure is among the important components of a comprehensive echocardiographic report. Previous studies noted wide limits of agreement using 2009 American Society of Echocardiography/European Association of Echocardiography guidelines, but reproducibility of 2016 guidelines update in estimating LV filling pressure is unknown.
Methods:
Echocardiographic and hemodynamic data were obtained from 50 patients undergoing cardiac catheterization for clinical indications. Clinical and echocardiographic findings but not invasive hemodynamics were provided to 4 groups of observers, including experienced echocardiographers and cardiology fellows. Invasively acquired LV filling pressure was the gold standard.
Results:
In group I of 8 experienced echocardiographers from the guidelines writing committee, sensitivity for elevated LV filling pressure was 92% for all observers, and specificity was 93±6%. Fleiss κ-value for the agreement in group I was 0.80. In group II of 4 fellows in training, sensitivity was 91±2%, and specificity was 95±2%. Fleiss κ-value for the agreement in group II was 0.94. In group III of 9 experienced echocardiographers who had not participated in drafting the guidelines, sensitivity was 88±5%, and specificity was 91±7%. Fleiss κ-value for the agreement in group III was 0.76. In group IV of 7 other fellows, sensitivity was 91±3%, and specificity was 92±5%. Fleiss κ-value for the agreement in group IV was 0.89.
Conclusions:
There is a good level of agreement and accuracy in the estimation of LV filling pressure using the American Society of Echocardiography/European Association of Cardiovascular Imaging 2016 recommendations update, irrespective of the experience level of the observer.
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Fluid Pressure over Flat Plate of Variable Width
The pressure distribution on the plate can be calculated by determining the force that acts on a differential area strip of the plate. Thus, the magnitude of the force is equal to the...
Pre-Procedural Guidelines for Assessing Blood Pressure
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...

