Related Experiment Video
Updated: Jan 30, 2026

Bacterial Detection & Identification Using Electrochemical Sensors
Published on: April 23, 2013
Identification of an internal cavity in the PhoQ sensor domain for PhoQ activity and SafA-mediated control
Kohei Yoshitani1,2, Eiji Ishii1,2, Katsuhide Taniguchi1
1a Department of Bioscience , Graduate School of Agriculture, Kindai University , Nara , Japan.
Abstract:
The PhoQ/PhoP two-component signal transduction system is conserved in various Gram-negative bacteria and is often involved in the expression of virulence in pathogens. The small inner membrane protein SafA activates PhoQ in Escherichia coli independently from other known signals that control PhoQ activity. We have previously shown that SafA directly interacts with the sensor domain of the periplasmic region of PhoQ (PhoQ-SD) for activation, and that a D179R mutation in PhoQ-SD attenuates PhoQ activation by SafA. In this study, structural comparison of wild-type PhoQ-SD and D179R revealed a difference in the cavity (SD (sensory domain) pocket) found in the central core of this domain. This was the only structural difference between the two proteins. Site-directed mutagenesis of the residues surrounding the SD pocket has supported the SD pocket as a site involved in PhoQ activity. Furthermore, the SD pocket has also been shown to be involved in SafA-mediated PhoQ control.
More Related Videos
10:28Sensitivity Enhancement of Soft Capacitive Pressure Sensors Using a Solvent Evaporation-Based Porosity Control Technique
Published on: March 24, 2023
08:49Identification of Mediators of T-cell Receptor Signaling via the Screening of Chemical Inhibitor Libraries
Published on: January 22, 2019
Related Concept Videos
Frequency-Domain Interpretation of PD Control
The proportional control gain, combined with the...
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Internal Receptors
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...