Effect of Elbow Position on Load to Failure in Olecranon Fracture Fixation: A Biomechanical Cadaveric Study
Robert W Lindeman1, Randal Morris, Paul Weatherby
1Department of Orthopaedic Surgery and Rehabilitation, The University of Texas Medical Branch, Galveston, TX.
Objectives:
This study evaluates if relative flexion or extension of the ulnohumeral joint affects the strength of repair in olecranon fractures treated with a precontoured locking plate.
Methods:
A cadaveric study was performed in matched pair cadaveric elbows. All soft tissue was dissected from the radius, ulna, and elbow of each specimen, leaving interosseous ligaments and joint capsules intact. Soft tissue from the humerus was dissected away, leaving only the triceps tendon and ulnar insertions intact. An oblique proximal to distal olecranon osteotomy was created in each specimen 1 cm from the tip of the olecranon. Internal fixation with standard precontoured locking plates and a Krackow augmentation suture with #2 FiberWire followed. Specimens were randomized to elbow position of 90 or 20 degrees° and loaded to failure via axial pull through the triceps. Load at failure, displacement at the time of failure, peak load, stiffness, and mechanism of failure was recorded and compared. The study was repeated a second time with the osteotomy more proximal, 0.6 cm creating a smaller fragment with less opportunities for locking screw fixation. This small fragment group was then tested as the large fragment group had.
Results:
There were no significant differences in load at failure, peak load, or stiffness between the elbow position in the large fragment group. Displacement at time of failure was significantly different, although not clinically relevant. Failure of fixation in this group was a mix of triceps avulsion and failure through fracture site. The smaller fragment group with less points of fixation demonstrated no statistically significant differences in any parameters. A majority of the failures were at the fracture site.
Conclusions:
Ulnohumeral position does not significantly affect overall construct strength even in olecranon fractures with small proximal fragments with limited points of fixation.
More Related Videos
08:04Proximal Cadaveric Femur Preparation for Fracture Strength Testing and Quantitative CT-based Finite Element Analysis
Published on: March 11, 2017
06:41A Minimally Invasive Model to Analyze Endochondral Fracture Healing in Mice Under Standardized Biomechanical Conditions
Published on: March 22, 2018
Related Concept Videos
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Position-effect Variegation
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Carbon-dioxide Fixation
Serial Position Effect
Impact Loading
In cases of elastic deformation,...