Related Experiment Video
Updated: Jan 30, 2026

Cell-Free Dot Blot as a Practical and Adaptable Immunoassay Platform for the Detection of Antibody Response in Human and Animal Sera
Published on: May 23, 2025
Commercial immunoassays for human relaxin-2
1Molecular Medicine Research Institute, 428 Oakmead Pkwy, Sunnyvale, CA, 94085, USA.
Abstract:
Several different immunoassays have been used in the commercial pharmaceutical development of serelaxin. These assays have been well validated for submission of GLP preclinical and clinical studies to the FDA and EU regulatory bodies. The requirements for these assays exceed that of most research assays commonly developed in academic research but have been and are currently available to academic researchers. Additionally, many human relaxin immunoassays are commercially available from a variety of vendors. Validation procedures for immunoassays are well understood and documented, however validation of these assays is often lacking or completely absent. The data derived from these assays must be questioned if the investigator does not supply information on the validation of the assay used, either from the supplier or through their own efforts. Many recent papers on determination of serum relaxin in clinical settings have recently been published. The assay used for this determination varies but generally is one of two commercially available. These manuscripts and the assay used is discussed. Direct comparisons of assays are lacking but some general conclusions can be drawn by comparing results from similar studies using different assays. There is disagreement among the results of the concentrations of serum relaxin from the use of different assays that raise questions on assay reliability. The differences in the quality of immunoassays used for detection of serum relaxin should be part of the decisions making process in choosing an assay. While the end user bears the ultimate responsibility to demonstrate the assay is valid for the stated claims, reviewers and editors also share responsibility for quality of published results.
Related Concept Videos
meta-Directing Deactivators: –NO2, –CN, –CHO, –⁠CO2R, –COR, –CO2H
2° Amines to N-Nitrosamines: Reaction with NaNO2
SN2 Reaction: Kinetics
In a chemical reaction, a relationship exists between the concentration of reactants and the rate at which the reaction proceeds. The study to measure this relationship is known as the kinetics of a chemical reaction. Kinetic studies are used to deduce the rate law of a chemical reaction, which provides information about the species involved during the transition state of the rate-determining step. Thus, kinetic studies help to derive the mechanism of a...
SN2 Reaction: Mechanism
The presence of the more electronegative halogen in the substrate creates a polarized carbon-halide bond. The halide pulls the electron cloud generating an electrophilic center at the carbon atom. Thus, the carbon atom carries a partial positive charge while the halide has a...
SN2 Reaction: Transition State
When the nucleophile approaches the electrophilic carbon with its lone pairs, the halide acts as a leaving group and moves away with the electron-pair bonded to the carbon. Dotted partial bonds represent the bonds being formed or broken...
SN2 Reaction: Stereochemistry
If the substrate is an achiral molecule at the α-carbon, the inversion of configuration is not...

