Related Experiment Video
Updated: Jan 30, 2026

Ultrasensitive Detection of Biomarkers by Using a Molecular Imprinting Based Capacitive Biosensor
Published on: February 16, 2018
Label-Free Capacitive Biosensor for Detection of Cryptosporidium
George Luka1, Ehsan Samiei2, Soroush Dehghani3
1School of Engineering, University of British Columbia, 333 University Way, Kelowna, BC V1V1V7, Canada. george.luka@alumni.ubc.ca.
Abstract:
Cryptosporidium, an intestinal protozoan pathogen, is one of the leading causes of diarrhea in healthy adults and death in children. Detection of Cryptosporidium oocysts has become a high priority to prevent potential outbreaks. In this paper, a label-free interdigitated-based capacitive biosensor has been introduced for the detection of Cryptosporidium oocysts in water samples. Specific anti-Cryptosporidium monoclonal antibodies (IgG3) were covalently immobilized onto interdigitated gold electrodes as the capture probes, and bovine serum albumin was used to avoid non-specific adsorption. The immobilization of the antibodies was confirmed by measuring the change in the contact angle. The detection was achieved by measuring the relative change in the capacitive/dielectric properties due to the formation of Cryptosporidium-antibody complex. The biosensor has been tested for different concentrations of Cryptosporidium. The results show that the biosensor developed can accurately distinguish different numbers of captured cells and densities on the surface of the biosensor. The number of Cryptosporidium oocysts captured on the electrode surface was confirmed using a fluorescein isothiocyanate (FITC) immunofluorescence assay. The response from the developed biosensor has been mainly dependent on the concentration of Cryptosporidium under optimized conditions. The biosensor showed a linear detection range between 15 and 153 cells/mm² and a detection limit of 40 cells/mm². The label-free capacitive biosensor developed has a great potential for detecting Cryptosporidium in environmental water samples. Furthermore, under optimized conditions, this label-free biosensor can be extended for detection of other biomarkers for biomedical and environmental analyses.
Related Concept Videos
Equivalent Capacitance
Equivalent Capacitance
The following strategies are adopted to calculate...
Capacitors and Capacitance
When the conductors are two identical parallel plates, it is called a parallel plate capacitor. When battery terminals are...
Design Example: Capacitance Multiplier Circuit
The circuit illustrated in Figure 1 below incorporates two op-amps, with the first operating as a voltage follower and the second acting as an inverting amplifier.
Capacitance: Single-Phase And Three-Phase Line
Single-Phase Lines
Consider a single-phase, two-wire transmission line with equal phase spacing energized by a voltage source. One conductor carries a uniform positive charge, while the other carries an equal negative charge. The capacitance C of the line can be derived from the voltage V between the conductors. For a one-meter section of the line, the capacitance is given...
Labeling Emotion

