Related Experiment Video
Updated: Jan 30, 2026

Scanning Electron Microscopic Evaluation of Surface Defects of Remover Retreatment File After Single and Multiple Uses
Published on: October 11, 2024
Effectiveness of different irrigation systems in the presence of intracanal-separated file
1Department of Endodontics, Faculty of Dentistry, Kocaeli University, Kocaeli, Turkey.
Abstract:
The aim of this study was to evaluate conventional syringe irrigation and three different irrigant activation techniques' effectiveness for smear layer removal in the absence and presence of intracanal-separated file (SF) fragment. Mandibular anterior teeth (160 total) with single canal were used and each root canal preparation was finished with the ProTaper Universal F1. The samples were randomly divided into eight equal groups with n = 20 in each group. The Protaper Universal F3 file was used to simulate intracanal file separation in four groups. To remove the smear layer, final irrigation for each group was performed with conventional syringe irrigation (CSI), EndoActivator, Vibringe, and passive ultrasonic irrigation (PUI). The roots were divided into two longitudinal parts and evaluated with scanning electron microscopy, and two observers scored smear layers at 1, 2, and 3 mm away from the minor foramen. The data were analyzed using the Kruskal-Wallis and Mann-Whitney U tests (p < .05). PUI significantly removed the smear layer better at all levels than other nonseparated file groups (p < .05). In the presence of intracanal SF, PUI had the most efficiency loss. Sonic techniques and CSI revealed statistically better smear layer removal efficiency than PUI at 3 mm level in the presence of SF (p < .05). The intragroup score analysis at all levels revealed that there were less smear layers at 3 mm than at 1 mm in all SF groups (p < .001). As a conclusion, sonic/ultrasonic methods did not yield better irrigant by-passing than CSI in the presence of intracanal SF.
Related Concept Videos
Design Example: Design of an Irrigation Channel
Second Order systems II
First Order Systems
When a first-order system is subjected to a unit-step input, its response is characterized by its transfer function. By applying the Laplace transform of the unit-step input to the transfer function, expanding the...
Second Order systems I
By reinterpreting the system, one can derive the closed-loop transfer function, which...
Buffer Effectiveness
The buffer capacity is the amount of acid or base that can be added to a given volume...
Separation of Sister Chromatids
At the onset of anaphase, separase, a proteolytic enzyme, is...

