Related Experiment Video
Updated: Jan 30, 2026

Design and Development of Aptamer–Gold Nanoparticle Based Colorimetric Assays for In-the-field Applications
Published on: June 23, 2016
Colorimetric detection and typing of E. coli lipopolysaccharides based on a dual aptamer-functionalized gold
Longjiao Zhu1,2, Shuting Li2,3, Xiangli Shao1,2
1Beijing Advanced Innovation Center for Food Nutrition and Human Health, College of Food Science & Nutritional Engineering, China Agricultural University, Beijing, 100083, China.
Abstract:
A rapid method for identification and typing of lipopolysaccharides (LPS) was developed by utilizing the different binding affinities between two kinds of gold nanoparticles (AuNPs) functionalized with two aptamers. Aptamers against ethanolamine and E. coli O111:B4 LPS were used to functionalize the AuNPs. The AuNPs functionalized with ethanolamine aptamer can bind to ethanolamine and are termed general probe (G-probe). The G-probe can recognize any type of LPS because ethanolamine is a component of every type of LPS. This causes a sandwich-mediated aggregation of the AuNPs and a color change from red to blue. The AuNPs functionalized with aptamer against the LPS of E. coli O111:B4 specifically bind to O111:B4 LPS and are termed specific probe (S-probe). By using these two probes, a logic typing method was developed. It can detect LPS in concentrations between 2.5 and 20 μg·mL-1 and with a 1 μg·mL-1 detection limit. In the authors' perception, the use of a dual aptamer-based colorimetric method has a large potential in terms of selective detection of microorganisms. Graphical abstract Two aptamer functionalized AuNP probes, G-probe and S-probe, were prepared for LPS typing and detecting. E. coli O111:B4 LPS was easily distinguished from O55:B5 LPS according to the signal output configurations (On & On Vs On & Off) of a general probe (G-probe) and a specific probe (S-probe).
More Related Videos
Related Concept Videos
Types of Functions I
Types of Functions II
T Cell Types and Functions
Th1 cells stimulate dendritic cells to express necessary co-stimulatory molecules on their surfaces for...
Types of Functions III
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Formation of Lipopolysaccharides

