Experimental design and measurement uncertainty in ligand binding studies by affinity capillary electrophoresis

Matthias Stein1, Rob Haselberg2, Mona Mozafari-Torshizi1

  • 1Technische Universität Braunschweig, Institute of Medicinal and Pharmaceutical Chemistry, Braunschweig, Germany.

Electrophoresis
|January 15, 2019
PubMed

Related Concept Videos

Ligand Binding Sites02:40

Ligand Binding Sites

Proteins are dynamic macromolecules that carry out a wide variety of essential processes; however, the activities of most proteins depend on their interactions with other molecules or ions, known as ligands.
Protein-ligand interactions are quite specific; even though numerous potential ligands surround a cellular protein at any given time, only a particular ligand can bind to that protein. Moreover, a ligand binds only to a dedicated area on the surface of the protein, known as the...
15.0K
Ligand Binding Sites02:40

Ligand Binding Sites

8.8K
Ligand Binding and Linkage00:49

Ligand Binding and Linkage

Allosteric proteins have more than one ligand binding site; the binding of a ligand to any of these sites influences the binding of ligands to the other sites. When a protein is allosteric, its binding sites are called coupled or linked.  In the case of enzymes, the site that binds to the substrate is known as the active site and the other site is known as the regulatory site. When a ligand binds to the regulatory site, this leads to conformational changes in the protein that can influence...
5.6K
Ligand Binding and Linkage00:49

Ligand Binding and Linkage

4.1K
Uncertainty in Measurement: Reading Instruments02:46

Uncertainty in Measurement: Reading Instruments

Counting is the type of measurement that is free from uncertainty, provided the number of objects being counted does not change during the process. Such measurements result in exact numbers. By counting the eggs in a carton, for instance, one can determine exactly how many eggs are there in the carton. Similarly, the numbers of defined quantities are also exact. For example, 1 foot is exactly 12 inches, 1 inch is exactly 2.54 centimeters, and 1 gram is exactly 0.001 kilograms. Quantities...
51.7K
Capillary Electrophoresis: Instrumentation01:20

Capillary Electrophoresis: Instrumentation

Capillary electrophoresis instrumentation typically consists of several key components. A high-voltage power supply generates the electric field necessary for the separation by connecting to an anode (the positively charged electrode) and a cathode (the negatively charged electrode) located in buffer reservoirs at each end of the capillary tube. The system includes a sample vial, a fused silica capillary tube coated with polyimide for mechanical strength through which the sample components...
1.2K