Related Experiment Video
Updated: Jan 30, 2026

Fabrication of Compressed Hosiery and Measurement of its Pressure Characteristic Exerted on the Lower Limbs
Published on: May 27, 2020
Intermittent calf compression reverses lower limb pooling and improves cardiovascular control during passive
Brooke C D Hockin1, Ian A Ruiz1, Garveen K Brar1
1Department of Biomedical Physiology and Kinesiology, Simon Fraser University, Burnaby, British Columbia, Canada; International Collaboration On Repair Discoveries (ICORD), University of British Columbia, Vancouver, British Columbia, Canada.
Abstract:
When upright, venous pooling and capillary filtration reduce the effective circulating volume and are key contributors to susceptibility to syncope (fainting). Recurrent syncope has a devastating impact on quality of life. Static calf compression garments are frequently prescribed for patients with syncope, but have questionable efficacy. Intermittent calf compression, which mimics the skeletal muscle pump to minimize pooling and filtration, is a potential alternative that holds promise for the management of syncope. We aimed to evaluate use of intermittent calf compression compared to commonly prescribed compression stockings, and determine the optimal intermittent calf compression paradigm, for improvement of orthostatic fluid shifts and cardiovascular control. We evaluated heart rate, blood pressure, stroke volume, cardiac output and peripheral resistance (finger plethysmography with Modelflow™) and calf pooling and filtration (calf circumference; strain gauge plethysmography) during a series of 10-min head-upright tilts. We first compared (protocol one) low (ICLF; 4 s on, 11 s off) and high (ICHF; 4 s on, 6 s off) frequency 0-100 mm Hg intermittent calf compression with static elastic and inelastic compression stockings and a placebo condition (n = 19, 5 males, aged 23.5 ± 0.1 years). We then compared (protocol two) ICLF applied at 0-40 mm Hg, 0-60 mm Hg, 0-80 mm Hg and 0-100 mm Hg as well as a placebo condition (n = 15, 5 males, aged 22.7 ± 0.5 years). The intervention order was randomized. In protocol one, all compression conditions significantly reduced calf circumference (p < 0.001) compared to placebo after 10-min upright; however, this reduction was greater in ICLF (-0.88 ± 0.18%) and ICHF (-1.14 ± 0.21%) conditions than both elastic (+0.49 ± 0.17%) and inelastic (-0.01 ± 0.19%) compression (p < 0.001). ICLF and ICHF, but not elastic or inelastic compression, were associated with improved stroke volume (p ≤ 0.001), allowing cardiac output to be maintained at a reduced heart rate (p < 0.001) without increases in vascular resistance responses, increasing hemodynamic reserve. ICHF showed no significant benefit over ICLF, evidenced by the lack of significant difference between ICLF and ICHF in any parameter measured. In protocol two, 0-60 mm Hg ICLF was considered the optimal intermittent compression because it was the lowest pressure that abolished the increase in calf circumference during orthostasis, while improving SV (p = 0.002), and reducing HR (p < 0.001) throughout tilt. Intermittent calf compression from 0 to 60 mm Hg ICLF is the optimal intermittent compression paradigm to ameliorate orthostatic fluid shifts and improve hemodynamic control. Commonly prescribed static calf compression garments do not improve orthostatic cardiovascular responses.
More Related Videos
06:58A Structured Rehabilitation Protocol for Improved Multifunctional Prosthetic Control: A Case Study
Published on: November 6, 2015
05:15Author Spotlight: Accessible M&M-Based Mouse Model for Investigating Binge Eating Disorder - Insights into Eating Behaviors, Anxiety, and Neural Mechanisms
Published on: January 10, 2025
Related Concept Videos
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
Active versus Passive Immunity
Active Immunity
Active immunity refers to the resistance one develops...
Overview of the Cardiovascular System
Heart
The heart is the central pump of the cardiovascular system that circulates blood throughout the body. It comprises two atria receiving the blood and two ventricles pumping blood out of the heart. Their rhythmic contractions, called heartbeats, ensure that blood flow remains continuous.
Blood Vessels
Blood...
Regulation of the Cardiovascular System
The regulation of the cardiovascular system involves the autonomic nervous system (ANS), baroreceptors, and chemoreceptors, ensuring that heart rate and blood pressure are appropriately modulated in response to varying physiological demands.
The ANS comprises two main divisions: the sympathetic and parasympathetic nervous systems. The sympathetic nervous system enhances...
Arteries of Lower Limbs
Veins of Lower Limbs
Formed by the union of the medial and lateral plantar veins, the posterior tibial vein, rising through the calf muscle, assimilates the fibular vein. The anterior tibial vein, a superior extension of the foot's dorsalis pedis vein, merges with the posterior tibial vein at the...