Related Experiment Video
Updated: Jan 30, 2026

The Impact of Motor Task Conditions on Goal-Directed Arm Reaching Kinematics and Trunk Compensation in Chronic Stroke Survivors
Published on: May 2, 2021
Hypersensitivity of trunk biomechanical model predictions to errors in image-based kinematics when using fully
A H Eskandari1, N Arjmand1, A Shirazi-Adl2
1Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran.
Abstract:
Recent advances in medical imaging techniques have allowed pure displacement-control trunk models to estimate spinal loads with no need to calculate muscle forces. Sensitivity of these models to the errors in post-imaging evaluation of displacements (reported to be ∼0.4-0.9° and 0.2-0.3 mm in vertebral displacements) has not yet been investigated. A Monte Carlo analysis was therefore used to assess the sensitivity of results in both musculoskeletal (MS) and passive finite element (FE) spine models to errors in measured displacements. Six static activities in upright standing, flexed, and extended postures were initially simulated using a force-control hybrid MS-FE model. Computed vertebral displacements were subsequently used to drive two distinct fully displacement-control MS and FE models. Effects of alterations in the reference vertebral displacements (at 3 error levels with SD (standard deviation) = 0.1, 0.2, and 0.3 mm in input translations together with, respectively, 0.2, 0.4, and 0.6° in input rotations) were investigated on the model predictions. Results indicated that outputs of both models had substantial task-dependent sensitivities to errors in the measured vertebral translations. For instance, L5-S1 intradiscal pressures (IDPs) were considerably affected (SD values reaching 1.05 MPa) and axial compression and shear forces even reversed directions as translation errors increased to 0.3 mm. Outputs were however generally much less sensitive to errors in measured vertebral rotations. Accounting for the accuracies in image-based kinematics measurements, therefore, it is concluded that the current measured vertebral translation errors at and beyond 0.1 mm are too large to drive biomechanical models of the spine.
Related Concept Videos
Hypersensitivities
Types of Hypersensitivities
Hypersensitivity reactions are categorized into four types: Type 1, Type 2, Type 3, and Type 4. Each type has a distinct mechanism...
Fundamental Attribution Error
Displacement Current
Position and Displacement
Kinematic Equations - I
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...

