Quantitative analysis of desomorphine in blood and urine using solid phase extraction and gas chromatography-mass
Jessica Winborn1, Sarah Kerrigan1
1Department of Forensic Science, Sam Houston State University, Box 2525, 1003 Bowers Blvd, Huntsville, TX 77341, United States of America.
Abstract:
Desomorphine, a semi-synthetic opioid, is a component of the street drug Krokodil. Despite continued reports of Krokodil use, confirmation via toxicological testing remains scarce. The lack of confirmed desomorphine reports may be in part due to the limited published analytical methodology capable of detecting desomorphine at forensically relevant concentrations. In an effort to assist with identification efforts, a robust analytical method was developed and validated. Solid phase extraction (SPE) and gas chromatography-mass spectrometry (GC-MS) were used to determine desomorphine in blood and urine using a deuterated analog as the internal standard. Data was acquired using selected ion monitoring (SIM) mode. Extraction efficiencies in blood and urine were 69% and 90%, respectively. The limits of quantitation in blood and urine were 5 ng/mL and 8 ng/mL, ten-fold lower than previously published methods. Intra- and inter-assay CVs were 2-4% (n = 3) and 3-7% (n = 15), respectively. The method was fully validated in accordance with published guidelines for forensic use. Furthermore, it provides a means by which desomorphine can be identified in toxicology specimens at forensically relevant concentrations, without the need for derivatization.
More Related Videos
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
08:14Extraction of Non-Protein Amino Acids from Cyanobacteria for Liquid Chromatography-Tandem Mass Spectrometry Analysis
Published on: December 9, 2022
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II