Picomolar detection of retinol binding protein 4 for early management of type II diabetes
Related Experiment Video
Updated: Jan 30, 2026

Real-time Analyses of Retinol Transport by the Membrane Receptor of Plasma Retinol Binding Protein
Published on: January 28, 2013
Anirban Paul1, Maria Serena Chiriacò2, Elisabetta Primiceri2
1Analytical & Environmental Science Division and Centralized Instrument Facility, CSIR-Central Salt and Marine Chemicals Research Institute (CSMCRI), Gijubhai Badheka Marg, Bhavnagar 364002, Gujarat, India; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India.
Abstract:
Type (II) diabetes is one of the major threats to mankind as it causes insulin resistance in human body and Retinol Binding Protein 4 (RBP4) is currently considered as a potential biomarker for early management of this disease. Hence a low-level detection of RBP4 is a very important task and for this purpose, a novel RBP4 biosensor has been developed using homemade plastic chip electrodes (PCEs) as a platform for self-assembled monolayer (SAM) of 4-ATP and further functionalization with glutaraldehyde. Anti RBP4 is used as biorecognition species and electrochemical impedance spectroscopy has been performed to detect different RBP4 concentrations plotted against charge transfer resistance. A wide concentration range from 100 fg/mL to 1 ng/mL has been tested and a low limit of detection (LOD) of 100 fg/mL has been achieved. This is the first report for fabrication of electrochemical biosensor of RBP4 using Ag-Ab interaction having such low LOD. The sensor is characterized by various physico-chemical techniques. Excellent reproducibility and quick measurement make this biosensor extremely useful for the biomedical industry.
Related Concept Videos
Diabetes: Management and Pharmacotherapy
Insulin remains the cornerstone of treatment for most patients with type 1 and many...
Diabetes Mellitus: Type 2 and Gestational
Diabetes Mellitus: Overview and Type I Subtype
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...
Factors Affecting Protein-Drug Binding: Protein-Related Factors
The physicochemical properties of a drug play a significant role in its ability to bind to proteins. Lipophilic drugs, which dissolve in fats, oils, and lipids, can be...
The Equilibrium Binding Constant and Binding Strength
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...

