Related Experiment Video
Updated: Jan 30, 2026

Training Dogs for Awake, Unrestrained Functional Magnetic Resonance Imaging
Published on: October 13, 2019
Pilot study using five methods to evaluate skin barrier function in healthy dogs and in dogs with atopic dermatitis
Danielle Cobiella1, Linda Archer1, Mary Bohannon1
1Department of Small Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, 2015 SW 16th Ave, Gainesville, FL, 32610, USA.
Background:
Atopic dermatitis is associated with skin barrier defects. In people, noninvasive techniques are used to quantify the skin barrier functionality. In dogs, transepidermal water loss (TEWL), stratum corneum hydration and pH have been used to assess skin barrier function. However, few studies have determined their repeatability.
Objective:
To assess the repeatability of measurements of skin hydration, TEWL, pH, skin absorbance and erythema in healthy and atopic dogs.
Animals:
Fifteen healthy and 15 atopic privately owned dogs.
Methods And Materials:
Three repeated measurements using Corneometer®, Skin-pH-Meter®, Colorimeter® and VapoMeter® were obtained from inguinal, axilla, pinna and interdigital space by three investigators. Intra- and interobserver variability (coefficient of variation, correlation coefficients and intraclass correlation coefficients) and difference between the two groups (t-test or Mann-Whitney U-test) were determined.
Results:
High repeatability and low variation were observed both intra- and interobservers for all devices except the VapoMeter®. The most repeatable device was the Skin-pH-Meter®, whereas the VapoMeter® was the device with the highest intra- and interobserver variability. Atopic dogs had a significantly increased pH (inguinal P = 0.03; axilla P = 0.02) and erythema (inguinal P = 0.01; axilla P = 0.02) compared to healthy dogs. No differences between the two groups were detected using the Corneometer®, VapoMeter® or Colorimeter® (tartrazine absorption).
Conclusion And Clinical Significance:
The results of this pilot study support the use of Corneometer®, Skin-pH-Meter® and Colorimeter® in the assessment of skin barrier function in dogs; further investigations to optimize measurements and confirm these results are needed.
More Related Videos
Related Concept Videos
Sensory Functions of the Skin
There are two main categories of receptors on the skin: capsulated and non-capsulated. The non-capsulated ones are mainly the pain receptors. The capsulated ones can be further categorized based on the...
Bioavailability Study Design: Healthy Subjects Versus Patients
Pilot and Numeric Relaying
Physiological Barriers
The blood endothelial barrier is the most porous of these. It allows all small ionized, un-ionized, and lipophilic molecules to pass through the endothelial lining into the interstitial space...
Serum Studies: Renal Function Tests
Mucosal Barrier of the Stomach
Within parietal cells, carbonic acid is first formed through the reaction of water and carbon dioxide. The dissociation of carbonic acid releases bicarbonate and hydrogen ions. The bicarbonate...

