Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
Ultra-Low Radiation Dose CT Fluoroscopy for Percutaneous Interventions: A Porcine Feasibility Study
Martin G Wagner1, J Louis Hinshaw1, Yinsheng Li1
1From the Departments of Medical Physics (M.G.W., Y.L., T.P.S., C.A.M.), Radiology (J.L.H., T.P.S., P.L., C.A.M., F.T.L.), Urology (J.L.H., F.T.L.), and Biomedical Engineering (T.P.S., F.T.L.), University of Wisconsin-Madison, 1111 Highland Ave, Madison, WI 53705.
Abstract:
Purpose To determine the feasibility of ultra-low-dose (ULD) CT fluoroscopy for performing percutaneous CT-guided interventions in an in vivo porcine model and to compare radiation dose, spatial accuracy, and metal artifact for conventional CT versus CT fluoroscopy. Materials and Methods An in vivo swine model was used (n = 4, ∼50 kg) for 20 procedures guided by 246 incremental conventional CT scans (mean, 12.5 scans per procedure). The procedures were approved by the Institutional Animal Care and Use Committee and performed by two experienced radiologists from September 7, 2017, to August 8, 2018. ULD CT fluoroscopic acquisitions were simulated by using only two of 984 conventional CT projections to locate and reconstruct the needle, which was superimposed on a previously acquired and motion-compensated CT scan. The authors (medical physicists) compared the ULD CT fluoroscopy results to those of conventional CT for needle location, radiation dose, and metal artifacts using Deming regression and generalized mixed models. Results The average distance between the needle tip reconstructed using conventional CT and ULD CT fluoroscopy was 1.06 mm. Compared with CT fluoroscopy, the estimated dose for a percutaneous procedure, including planning acquisitions, was 0.99 mSv (21% reduction) for patients (effective dose) and 0.015 µGy (97% reduction) for physicians (scattered dose in air). Metal artifacts were statistically significantly reduced (P < .001, bootstrapping), and the average registration error of the motion compensation was within 1-3 mm. Conclusion Ultra-low-dose CT fluoroscopy has the potential to reduce radiation exposure for intraprocedural scans to patients and staff by a factor of approximately 500 times compared with conventional CT acquisition, while maintaining image quality without metal artifacts. © RSNA, 2019.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Biological Effects of Radiation
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Bioavailability Study Design: Single Versus Multiple Dose Studies
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Nursing Interventions I: Taxonomy of Nursing Interventions
A nursing intervention is a treatment or action based on scientific concepts and knowledge from the nursing, behavioral, and physical sciences. Identifying and prioritizing nursing interventions based on the desired outcome...