Dual-mode Imaging of Cutaneous Tissue Oxygenation and Vascular Function
Published on: December 8, 2010
Noninvasive assessment of aorta-coronary saphenous vein bypass graft patency using thermocouple
Abstract:
Noninvasive monitoring of patency of aorta-coronary bypass grafts can be achieved with reasonable accuracy using the thermocouple. This method is consisted of attaching the thermocouple to the surface of grafted vein during surgery and judging the patency by rapid injection of iced solution into peripheral vein. Patient grafted vein will show the thermal change after injecting iced solution. On the contrary, occluded graft will show no thermal change. As this thermal curve is a thermodilution curve by a single injection and is measured from the outside of the vessel, thermal change depends on the temperature and the quantity of the injected solution, cardiac output, body temperature, and loss of indicator temperature along the way to the thermocouple. When the grafted vein is patent, the same thermal curves are recorded regardless of the amount of the flow, and zero flow resulted in disappearance of curve. Initially, the method was evaluated in dogs and the appropriateness was verified. Subsequently, this method was applied to 16 vein grafts of 12 patients undergoing aorta-coronary bypass surgery. Ten or 15 ml of iced solution was injected through inferior vena cava or antecubital vein and the thermal change of the grafted vein was recorded for 1-4 weeks after the operation. Fourteen grafted veins were judged to be patent and 2 were occluded. The comparison of the results by this method with coronary angiography undergone at 4 weeks after the operation showed no false positive case but 1 false negative case. This extravascular observation of the thermodilution curve is a convenient method for judging whether vein graft is patent or not.
More Related Videos
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...