Adsorption of phosphorus by using magnetic Mg-Al-, Zn-Al- and Mg-Fe-layered double hydroxides: comparison studies and
Tianchen Sheng1, Zhen Zhang1, Yuncheng Hu1
1Department of Municipal Engineering, School of Civil and Hydraulic Engineering, Hefei University of Technology, Hefei, 230009, China.
Abstract:
Mg-Al, Zn-Al and Mg-Fe magnetic layered double hydroxide (LDH) adsorbents were synthesized. The adsorption effect and influencing factors of these adsorbents were explored, and the adsorption mechanism of phosphorus was studied with advanced instruments. The results showed that the best adsorption performance was observed when the molar ratio of metals was 3 for the magnetic LDH adsorbents, and the maximum adsorption amount for phosphorus was 74.8, 80.8 and 67.8 mg/g for Mg-Al, Zn-Al and Mg-Fe LDHs, respectively. Pseudo-second-order kinetics could be used to describe the adsorption process of phosphorus onto the magnetic LDHs. The adsorption of phosphorus onto the magnetic LDHs was an exothermic process. Lower temperatures were favourable for adsorption, and the adsorption of phosphorus onto the magnetic LDHs was a spontaneous process. When the solid-liquid ratios were 0.10 g/L, 0.10 g/L and 0.05 g/L for Mg-Al, Zn-Al and Mg-Fe magnetic LDHs, respectively, the highest adsorption amount of phosphorus was achieved for each magnetic LDH. The maximum adsorption amount was observed at pH values of 6.0-8.0. The inhibitory effect of HCO3- on the adsorption capacity of phosphorus onto the magnetic LDHs was the strongest at a higher HCO3- concentration level. The relative content of -OH significantly reduced after adsorption of phosphorus by the FTIR analysis, which indicated that the mechanism of phosphorus removal was mainly through the exchange between hydroxyl on the adsorbent surface and phosphorus in water. XPS studies showed that oxygen provided electrons during the adsorption of phosphorus.
Related Concept Videos
Analyte Adsorption and Distribution
The Phosphorus Cycle
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Fixing Double-strand Breaks
Chirality at Nitrogen, Phosphorus, and Sulfur
A consequence of chirality is the need for enantiomeric resolution. While this is theoretically possible for all...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...


