Related Experiment Video
Updated: Jan 30, 2026

Author Spotlight: A Novel 3D-Printed Titanium Implant for Minimally Invasive Treatment of Hip Dysplasia in Young Dogs
Published on: April 19, 2024
Technical Repeatability and Reproducibility of the Stress Radiographs Performed with the Vezzoni-Modified Badertscher
Mileva Bertal1, Lieve De Rycke1, Aldo Vezzoni2
1Department of Medical Imaging and Orthopaedics, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium.
Objective:
The aim of this study was to evaluate the repeatability and reproducibility of the radiographical stress technique using the Vezzoni-modified Badertscher distension device (VMBDD).
Materials And Methods:
Stress radiographs of 10 dogs obtained with the VMBDD were performed consecutively by two different operators and then measured twice by a third veterinarian. The technical repeatability was first assessed individually for the two operators who took the stress radiographs, followed by the technical reproducibility. The obtained variances were used to calculate the 95% limits of agreement for the measurement repeatability, the technical repeatability and the technical reproducibility.
Results:
Both the technical repeatability and reproducibility of the VMBDD technique were good, with the 95% limits of agreement of the measurement repeatability and technical repeatability equalling ± 0.07 overall, and the 95% limits of agreement of the technical reproducibility being ± 0.09.
Clinical Significance:
These results, in combination with the previous results for the measurement of the laxity index, support the use of the VMBDD as a reliable in-house evaluation method to assess the hip joint by trained clinicians. For screening purposes, however, we suggest to limit the number of evaluators, to limit the variability.
Related Concept Videos
Responses to Salt Stress
Responses to Heat and Cold Stress
Stress
General State of Stress
Specifically, consider a tetrahedral element where one face, labeled XYZ, is perpendicular to the line OA, and the remaining faces align with the coordinate axes with point O as the origin. At any point, such as point O, the stress tensor can be used to determine the stress...
Modified Boxplots
However, the box plot does not tell the reader about outliers - values that lie far from the center of the data. We can modify the standard box and whisker plot to identify the outliers and visualize the actual spread of the data in a sample.
Initially, we calculate the adjusted...
Stress Prevention and Stress Management Techniques II
Type A Personality: Driven and Easily Stressed
Individuals with Type A personalities are often highly competitive and ambitious and operate with a strong sense of urgency. Commonly labeled as...

