Related Experiment Video
Updated: Jan 30, 2026

A Model to Simulate Clinically Relevant Hypoxia in Humans
Published on: December 22, 2016
Combined Multichannel Intraluminal Impedance and High-resolution Manometry Improves Detection of Clinically Relevant
Byeong Geun Song1, Yang Won Min1, Hyuk Lee1
1Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
Background/Aims:
Esophagogastric junction outflow obstruction (EGJOO) is a diagnostically heterogeneous group with variable clinical relevance. We studied whether evaluation of bolus transit by multichannel intraluminal impedance (MII) is useful for discriminating clinically relevant EGJOO.
Methods:
A total 169 patients diagnosed as having EGJOO between June 2011 and February 2018 were analyzed. All the patients received a combined MII and high-resolution manometry (CMII-HRM). MII was reported as having abnormal liquid bolus transit (LBT) if < 80% of swallows had complete bolus transit. EGJOO was defined as a median integrated relaxation pressure of > 20 mmHg and when the criteria for achalasia were not met. Patients who progress to achalasia, show significant passage disturbance, or require pneumatic dilatation were defined as having a clinically relevant EGJOO.
Results:
Among the patients with EGJOO (n = 169), the clinically relevant group (n = 10) is more likely to have dysphagia (100% vs 25.2%, P < 0.001), compartmentalized pressurization (CP; 90.0% vs 22.0%, P < 0.001), and abnormal LBT (100% vs 66.7%, P = 0.032) compared to the non-relevant group (n = 159). The combination of dysphagia, CP, and abnormal LBT showed the best predictive power for clinically relevant EGJOO (sensitivity 90%, specificity 92.5%, positive predictive value 42.9%, negative predictive value 99.3%, positive likelihood ratio 11.9, and negative likelihood ratio 0.1). When CMII-HRM was used, an additional 8.3% of clinically relevant EGJOO cases were identified as compared with HRM alone.
Conclusion:
Clinically relevant EGJOO can be predicted using CMII-HRM.
Related Concept Videos
Impedance Combination
Clinically Relevant Drug Product Specifications: Methods of Establishment
P-N junction
Impedances and Admittance
Impedance is a measure of resistance to sinusoidal current flow in an AC circuit. Unlike their behavior in DC circuits, where inductors appear as short circuits and capacitors as open circuits, the behavior of these components in AC...
The Neuromuscular Junction
Anchoring Junctions