Related Experiment Video
Updated: Jan 30, 2026

Fabricating High-viscosity Droplets using Microfluidic Capillary Device with Phase-inversion Co-flow Structure
Published on: April 17, 2018
Organic-free, versatile sessile droplet microfluidic device for chemical separation using an aqueous two-phase system
Matthias Hermann1, Prashant Agrawal, Iris Koch
1Department of Chemistry, Queen's University, 90 Bader Lane, Kingston, Ontario K7L 3N6, Canada. Richard.oleschuk@chem.queensu.ca.
Abstract:
This work presents a novel portable, versatile sessile droplet microfluidic (SDMF) device to perform liquid manipulation operations such as confining, splitting and colorimetric detection. Furthermore, chemical isolations based on an aqueous two-phase system (ATPS) for separating an analyte of choice from a complicated sample matrix can be carried out. ATPS extractions can replace conventional liquid-liquid extractions and take away the need for harmful organic solvents. Superhydrophobic (SH) surfaces were fabricated from a commercially available material, Ultra-Ever Dry® (UED®). On these SH surfaces, surface energy traps (SETs) were produced either by air plasma treatment (simultaneously) or laser micromachining (sequentially) to dock/pin an ATPS containing droplet onto the surface. Splitting of droplets or removing a precise volume of the top phase from a pinned extraction system was achieved with a sandwich-chip approach. For this, an additional SET patterned substrate was placed on top of the droplet and subsequently lifted. This multipurpose platform was used to isolate Cd from a mixture of several other metal ions (i.e. Mn, Ni, Cu, Pb, Fe) for its subsequent interference-free detection. An ATPS consisting of sodium sulfate and polyethylene glycol (PEG) as phase forming components and potassium iodine as extractant allowed separation of cadmium with an extraction efficiency of q(Cd2+) = 98.5%. Using a portable, cost-effective, smartphone-based UV/vis spectrometer, Cd was detected with a LoD of 3.4 ppm. Alternatively, the multipurpose platform can also be used as sampling platform for a benchtop UV/vis spectrometer, where a LoD of 0.53 ppm was obtained. Potential applications of the presented platform include sample preparation and separation that can be achieved by aqueous two-phase extractions, such as proteins, antibodies, DNA, cells, organic molecules and metal ions.
Related Concept Videos
Chemical Reactions in Aqueous Solutions
Organic Compounds
Chemical Equations
Aqueous Solutions and Heats of Hydration
When ionic compounds dissolve in water, the ions in the solid separate and disperse uniformly throughout the solution because water molecules surround and solvate the ions, reducing the strong electrostatic forces between them. This process...
Phase Diagrams
Chemical Reactions
Chemical Reactions Rearrange Atoms into New Substances
A chemical reaction takes starting materials—the reactants—and changes them...

