Intravoxel Incoherent Motion Combined With Dynamic Contrast-Enhanced Perfusion MRI of Early Cervical Carcinoma:
Xiangsheng Li1, Shandong Wu2, Dechang Li3
1Department of Radiology, Air Force General Hospital, People's Liberation Army, Beijing, China.
Background:
The identification of hypoxia inducible factor (HIF-1α) expression is helpful for the quantitative assessment of tumor hypoxia. The application of multimodal imaging techniques may play a part in the assessment of HIF-1α expression of cervical carcinoma.
Purpose:
To investigate the correlations between multiple imaging parameters and HIF-1α expression of early cervical carcinoma and to determine whether tumor hypoxia can be predicted using multisequence imaging parameters.
Study Type:
Prospective observational.
Population:
One hundred patients with early cervical carcinoma.
Field Strength/Sequences:
3.0 T MRI including intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) and dynamic contrast-enhanced (DCE) perfusion MRI sequences.
Assessment:
DCE-MRI and IVIM DWI were performed for all patients. The imaging parameters included volume transfer constant (Ktrans ), rate constant (Kep ), extravascular extracellular volume fraction (Ve ), D, D*, and f.
Statistical Tests:
The comparisons of imaging parameters between two independent groups were performed using the Mann-Whitney U-test. Multiple linear regression analysis was performed to determine the correlation between multiple imaging parameters and HIF-1α expression. The diagnostic ability of DCE-MRI, IVIM DWI, and the combination of two techniques for discriminating high-expression and low-expression groups were analyzed.
Results:
The high-expression group had a lower Ktrans or Kep value than the low-expression group (P = 0.03; 0.02), while the high-expression group had a higher Ve value than the low-expression group (P = 0.03). The high-expression group had a higher D or f value than the low-expression group (P = 0.02; 0.02). Ktrans , Kep , D, Ve , and f values were independently correlated with HIF-1α expression. The sensitivity or accuracy of a combined method was higher than that of DCE-MRI or IVIM DWI individually (P = 0.03, 0.02; 0.04, 0.03).
Data Conclusion:
The combination of DCE-MRI and IVIM DWI can improve the diagnostic ability of discriminating different HIF-1α expression levels for early cervical tumors.
Level Of Evidence:
1 Technical Efficacy Stage: 2 J. Magn. Reson. Imaging 2019;50:918-929.
More Related Videos
08:22Combined Intravital Microscopy and Contrast-enhanced Ultrasonography of the Mouse Hindlimb to Study Insulin-induced Vasodilation and Muscle Perfusion
Published on: March 20, 2017
11:38In vivo Imaging of Optic Nerve Fiber Integrity by Contrast-Enhanced MRI in Mice
Published on: July 22, 2014
Related Concept Videos
Dynamics of Circular Motion
Any acceleration must be produced by some force. Therefore, any force or combination of forces can cause centripetal acceleration. A few examples include the tension in the rope on a...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Dynamics Of Circular Motion: Applications
Correlations
Correlation and Causation
Correlation versus Causation
If the dependent variable increases or decreases when the independent variable increases, there is a positive or negative...
Chromatin Position Affects Gene Expression
Topologically Associated Domains (TADs)
The 3-dimensional positioning of chromatin in the nucleus influences the...