Cardiac motion correction for improving perfusion defect detection in cardiac SPECT at standard and reduced doses of
Chao Song1, Yongyi Yang1, Miles N Wernick1
1Medical Imaging Research Center and Department of Electrical and Computer Engineering, Illinois Institute of Technology, Chicago, IL, United States of America.
Abstract:
In cardiac SPECT perfusion imaging, cardiac motion can lead to motion blurring of anatomical detail and perfusion defects in the reconstructed myocardium. In this study, we investigated the potential benefit of cardiac motion correction for improving the detectability of perfusion defects. We considered a post-reconstruction motion correction (PMC) approach in which the image motion between two cardiac gates is obtained with optical flow estimation. In the experiments, we demonstrated the proposed post-reconstruction motion correction with optical flow estimation (PMC-OFE) approach on a set of clinical acquisitions from 194 subjects. We quantified the detectability of perfusion defects in the reconstructed images by using the total perfusion deficit scores, calculated by the clinical software tool QPS, and conducted a receiver-operating-characteristic (ROC) study to obtain the detection performance. Besides imaging with conventional standard dose, we also evaluated the approach for reduced dose SPECT imaging where the imaging dose was retrospectively reduced to 50%, 25%, and 12.5% of the standard dose. The proposed PMC-OFE approach achieved at each dose level higher area-under-the-ROC-curve (AUC) for perfusion defect detection than the traditional approach of using ungated data (Non-MC) (p -value < 0.05); in particular, with half dose, PMC-OFE achieved AUC = 0.813, which is comparable to Non-MC with standard dose (AUC = 0.795). Moreover, the proposed PMC-OFE approach also outperformed the 'Motion Frozen' (MF) method implemented in the clinical quantitative gated SPECT (QGS) software. In particular, at 25% and 12.5% of standard dose, the AUC values obtained by PMC-OFE are 0.788 and 0.779, respectively, compared to 0.758 and 0.731 for MF (p -value < 0.05).
Related Concept Videos
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
The Cardiac Cycle
The Process
Electrical signals—sent from the sinoatrial (SA) node in the right atrial wall to the atrioventricular (AV) node between the right atrium and right ventricle—cause both atria to simultaneously contract. When the signal reaches the AV node, it pauses for approximately a tenth of a second, allowing the atria to contract and...
Cardiac Cycle
During the cardiac cycle, blood flow through the heart is regulated entirely by changing pressure gradients. This sequence of events begins with the heart in a state of total relaxation, known as mid-to-late diastole, during which blood passively flows from...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...