Related Experiment Video
Updated: Jan 30, 2026

Determination of the Excitation and Coupling Rates Between Light Emitters and Surface Plasmon Polaritons
Published on: July 21, 2018
Observation of terahertz plasmon and plasmon-polariton splitting in a grating-coupled AlGaN/GaN heterostructure
Abstract:
Plasmon in two-dimensional electron gas (2DEG) has long been considered as a promising active medium for terahertz emitters and detectors. However, the efficiency of terahertz plasmonic devices is severely limited by the high damping rate of plasma wave in solid state. In addition to the enhancement of plasmon lifetime by using 2DEGs with higher carrier mobility, engineering on the boundary condition and electromagnetic environment of plasmon cavity helps to preserve the plasmon states. Here we report on terahertz reflection spectroscopy of plasmon states in a grating-coupled AlGaN/GaN-2DEG plasmonic device at 7 K in equilibrium with ambient blackbody irradiation. Localized plasmon states and plasmon-polariton states were observed when the core plasmonic device is integrated with a silicon lens and when it is embedded in a terahertz Fabry-Pérot cavity, respectively. Simulation results including the reflection spectra and total reflection power agree well with the measured results. The Rabi splitting is found to be inversely proportional to the resonance frequency, and follows a linear relation with the square root of the sheet electron density. A normalized coupling ratio, ΩRω0≈0.13, is achieved between the Rabi splitting ΩR and the resonance frequency ω0. The coupling ratio could be further increased to allow for ultrastrong coupling between terahertz photons and plasmons.
Related Concept Videos
Naturalistic Observations
¹H NMR: Complex Splitting
Splitting diagrams or splitting tree diagrams are routinely used to depict such complex couplings. While drawing splitting diagrams, the splitting with the larger coupling constant is usually applied...
Spin–Spin Coupling: Two-Bond Coupling (Geminal Coupling)
The central atom need not be NMR-active because its electrons are affected by the electron polarization of the spin-active atoms. However, spin information is transmitted less effectively than in one-bond coupling, and 2J values are usually weaker than 1J values. The energy of...
Spin–Spin Coupling: Three-Bond Coupling (Vicinal Coupling)
The extent of coupling depends on the C‑C bond length, the two H‑C‑C angles, any electron-withdrawing substituents, and the dihedral angle between the involved orbitals. The...
G-protein Coupled Receptors
Spin–Spin Coupling: One-Bond Coupling