Evaluation of a Novel Water-Based Volumetric Device for Measuring Upper Limb Lymphedema: First Experience with
Joost A G N Wolfs1, Ennie Bijkerk1, Rutger M Schols1
1Department of Plastic and Reconstructive Surgery, Maastricht University Medical Center +, Maastricht, The Netherlands.
Abstract:
Lymphedema is a chronic, progressive disease consisting of tissue swelling resulting from excessive retention of lymphatic fluid. Measuring upper limb volume is crucial in patients to detect disease progression and to study the effects of treatment. The aim is to assess the validity and reliability of a newly developed system, Peracutus Aqua Meth, for measuring the upper limb volume compared with the gold standard water volumetry device. (In this study, the Bravometer was used). Healthy volunteers were recruited in October 2017. Three measurements were performed per device. The obtained data were recorded per measurement, device, and researcher. Primary outcome was to determine the validity and reliability of the Peracutus Aqua Meth. Secondary outcomes were intra- and interrater reliability, measurement time, self-reported participant satisfaction, and influence of body mass index (BMI). Thirty-nine healthy volunteers were included. Mean differences in the validity in the Peracutus Aqua Meth and Bravometer were 47.26 and 78.16 mL, respectively (p = 0.04), with a Pearson's r of 0.99. Intra- and interrater reliability of the Peracutus Aqua Meth were both 0.99, in the Bravometer 0.96 and 0.97, respectively (p < 0.01). The Peracutus Aqua Meth required more time to measure and obtained lower scores in the participant satisfaction questionnaire. BMI was statistically associated with the measurements (p < 0.01). The first prototype of the Peracutus Aqua Meth is proven to be an accurate and reliable device for measuring the volume of the arm. Further improvements are needed in case of usability, time management, and participant satisfaction.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Development of the Lymphatic System
The first lymph sacs to form are the paired jugular lymph sacs located at the junction of the internal jugular and subclavian veins. From these sacs, lymphatic capillary plexuses extend to the thorax, upper limbs, neck, and head, eventually forming lymphatic vessels. Each jugular lymph sac maintains a...
Pre-Procedural Guidelines for Assessing Blood Pressure