Incidental myocardial perfusion defect detected on ECG-gated CT aortogram
Yonah B Esterson1, Aryeh Y Esterson2, Danuta Jankowska3
1Department of Radiology, Northwell Health System, The Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, 300 Community Drive, Manhasset, NY 11030, USA.
Abstract:
We report the case of a 49-year-old man with a history of diabetes and hypertension who presented to the emergency room with intermittent chest pain radiating to the back for one day. An electrocardiogram-gated CT aortogram excluded the emergency department's primary consideration of aortic dissection, but incidentally revealed a myocardial perfusion defect and corresponding coronary artery stenosis. Cardiac catheterization performed the following day confirmed the CT findings and the patient underwent angioplasty and stent placement. We show that despite a different protocol than coronary CTA or myocardial perfusion CT, a gated CTA for dissection (CT aortogram) is capable of detecting resting perfusion abnormalities in patients presenting to the emergency room with chest pain.
More Related Videos
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
08:28Induction of Myocardial Infarction and Myocardial Ischemia-Reperfusion Injury in Mice
Published on: January 19, 2022
Related Concept Videos
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Underflow Gates
Ligand-Gated Ion Channel Receptor: Gating Mechanism
Lumber Defects
Shakes are minor fractures that run along or across the wood's annual rings, while wane is...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Non-gated Ion Channels
Compared to the gated ion channels, the non-gated channels, also known as leakage or passive channels, have no gating mechanism....