Related Experiment Video
Updated: Jan 30, 2026

Elemental-sensitive Detection of the Chemistry in Batteries through Soft X-ray Absorption Spectroscopy and Resonant Inelastic X-ray Scattering
Published on: April 17, 2018
Operando X-ray absorption spectroscopy study of the Fischer-Tropsch reaction with a Co catalyst
Chandrani Nayak1, Preeti Jain2, C P Vinod2
1Atomic and Molecular Physics Division, Bhabha Atomic Research Centre, Mumbai 400085, India.
Abstract:
This article describes the setting up of a facility on the energy-scanning EXAFS beamline (BL-09) at RRCAT, Indore, India, for operando studies of structure-activity correlation during a catalytic reaction. The setup was tested by operando X-ray absorption spectroscopy (XAS) studies performed on a Co-based catalyst during the Fischer-Tropsch reaction to obtain information regarding structural changes in the catalyst during the reaction. Simultaneous gas chromatography (GC) measurements during the reaction facilitate monitoring of the product gases, which in turn gives information regarding the activity of the catalyst. The combination of XAS and GC techniques was used to correlate the structural changes with the activity of the catalyst at different reaction temperatures. The oxide catalyst was reduced to the metallic phase by heating at 400°C for 5 h under H2 at ambient pressure and subsequently the catalytic reaction was studied at four different temperatures of 240, 260, 280 and 320°C. The catalyst was studied for 10 h at 320°C and an attempt has been made to understand the process of its deactivation from the XANES and EXAFS results.
More Related Videos
06:00Biological Samples Preparation for Speciation at Cryogenic Temperature using High-Resolution X-Ray Absorption Spectroscopy
Published on: May 27, 2022
06:48Fluid-cell Raman Spectroscopy for operando Studies of Reaction and Transport Phenomena during Silicate Glass Corrosion
Published on: May 9, 2025
Related Concept Videos
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Molecular Spectroscopy: Absorption and Emission
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Atomic Spectroscopy: Absorption, Emission, and Fluorescence