In vitro analysis of urinary stone composition in dual-energy computed tomography
Monika Stępień1, Robert Chrzan1, Wojciech Gawlas2
1Department of Radiology, Jagiellonian University in Kraków, Collegium Medicum, Poland.
Purpose:
Dual energy computed tomography (DECT) is a new method of computed tomography (CT) imaging, allowing the assessment of not only the object's morphology, but also its composition. The aim of the study was to evaluate the potential of in vitro DECT evaluation of urinary stones' chemical composition.
Material And Methods:
Six samples of surgically removed renal stones were scanned using DECT and analyzed by scanner vendor software. Uric acid stones were marked red and calcium stones white by the software. The real composition of the stones was finally verified using physicochemical laboratory analysis.
Results:
In 5 out of 6 samples, the composition of stones in DECT (3 samples identified as uric acid and 2 samples as calcium) was consistent with the physicochemical analysis (3 samples identified as uric acid, 1 as calcium phosphate, 1 as calcium oxalate). In DECT it was not possible to determine more precisely the type of calcium compounds (calcium phosphate vs. calcium oxalate) as established in the physicochemical analysis.In one stone identified in physicochemical analysis as uric acid, DECT detected a composite layered structure containing both uric acid and calcium compounds.
Conclusions:
DECT allows uric acid to be distinguished from calcium urinary tract stones, which is crucial in the choice of appropriate therapy. Using the available hardware and software, it was not possible to more accurately distinguish types of calcified stones. Evaluation of the stone type in DECT may be limited in the case of mixed chemical composition.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Types of Building Stone
Igneous rocks are formed from the solidification of magma or lava. An example is granite, known for its durability and resistance to weathering, making it ideal for parts of...
Quarrying of Stone
One common method involves using a diamond belt saw to cut large blocks from the quarry face. These blocks can be about 50 feet long and 12 feet high. After the initial vertical cut, drilling is performed at the base of the...
Stone Masonry
What is Energy?