Related Experiment Video
Updated: Jan 30, 2026

Building Langmuir Probes and Emissive Probes for Plasma Potential Measurements in Low Pressure, Low Temperature Plasmas
Published on: May 25, 2021
Pressure-varying Langmuir parameters and stepped nitrogen adsorption on alumina and silica
Trevor C Brown1, David J Miron, Christopher M Fellows
1School of Science and Technology, University of New England, Armidale, New South Wales 2351, Australia. Trevor.Brown@une.edu.au.
Abstract:
Insights into surface structures and thermodynamics are provided for nitrogen adsorption on two nonporous alumina adsorbents and two macroporous silica adsorbents by modelling high-resolution data using the simple Langmuir isotherm equation combined with pressure-varying flexible least squares. The fitted parameters, maximum adsorption capacity and standard Gibbs energy change for each adsorbent show multiple steps that are assumed to be indicative of transitions to different complete monolayer and multilayer structures. Pressure-varying N2 cross-sectional areas for three of the adsorbents are calculated by assuming that one of the steps is the Brunauer-Emmett-Teller monolayer with molecular area 16.2 Å2. The silica with added octyldimethylsilyl groups has pressure-varying parameter profiles that differ from the other adsorbents and here the N2 cross-sectional area is assumed to be 21.3 Å2 to ensure consistency with the literature surface area. Seven monolayers and multilayers are identified across the four adsorbents, and corresponding molecular areas compare favourably with reported values. At low pressures, adsorption occurs at the strongest sites, and is localised and dependent on surface heterogeneity and topography. Up to five complete, two-dimensional lattice structures are apparent in the mid-pressure ranges. At high pressures, multilayers and liquefaction points are observed and are independent of surface composition and heterogeneity.
More Related Videos
10:44Preparation of Biomass-based Mesoporous Carbon with Higher Nitrogen-/Oxygen-chelating Adsorption for CuII Through Microwave Pre-Pyrolysis
Published on: February 12, 2019
09:46Adsorption Device Based on a Langatate Crystal Microbalance for High Temperature High Pressure Gas Adsorption in Zeolite H-ZSM-5
Published on: August 25, 2016
Related Concept Videos
The Nitrogen Cycle
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Analyte Adsorption and Distribution
Gradually Varying Flow
Rapidly Varying Flow