Related Experiment Video
Updated: Jan 30, 2026

Measurement of Greenhouse Gas Flux from Agricultural Soils Using Static Chambers
Published on: August 3, 2014
Detachable Trap Preconcentrator with a Gas Chromatograph-Mass Spectrometer for the Analysis of Trace Halogenated
Doohyun Yoon1,2, Jeongsoon Lee1,2, Jeong Sik Lim1,2
1Center for gas analysis , Korea Research Institute of Standards and Science (KRISS) , Gajeong-ro 267 , Yuseong-gu, Daejeon , 34113 , Republic of Korea.
Abstract:
A detachable trap preconcentrator coupled with a gas chromatograph-mass spectrometer (GC-MS) was developed for measuring trace amounts of anthropogenic halogenated greenhouse gases such as hydrofluorocarbons (HFCs) and nitrogen trifluoride (NF3). Hayesep D cooled to -135 °C was used as an adsorbent for preconcentrating the target analytes. A differential trapping method was applied to remove major interfering substances such as CO2, N2, and O2 in order to ensure sufficient sampling volume of secondary injection trap. This was accomplished without using any CO2-removal agent such as molecular sieve adsorbents. Consequently, the temperature of the primary transfer trap was set to -75 °C for selective desorption of a significant amount of CO2 that could be vented out. In the meantime, the major components of air, e.g., N2 and O2, were vented out before transferring the analytes to the secondary injection trap, in order to protect the gas plumbing from pressure shock induced by rapid temperature ramping over 100 °C/min in the secondary trap. When the traps were heated, linear motion was operated to detach them from the copper baseplate on the freezer, thereby restricting heat transfer to the freezer and maintaining the freezer close to the background temperature of -135 °C. This trap design is a key improvement to address the insufficient cooling capacity of the employed freezer, allowing sensitive detection of trace halogenated greenhouse gases in GC-MS. NF3 and various HFCs at ambient levels were quantitatively and qualitatively measured with a precision of 0.35% at rates below 45 min/cycle. In particular, the limit of detection for NF3 was evaluated to be 0.2 pmol/mol, with linear responses at ambient concentration.
More Related Videos
Related Concept Videos
Chemical Stoichiometry and Gases: Using Ideal Gas Law to Determine Moles
Halogens
Mass Spectrometers
Applications of the Ideal Gas Law: Molar Mass, Density, and Volume
Noble Gases
The elements in group 18 are noble gases (helium, neon, argon, krypton, xenon, and radon). They earned the name “noble” because they were assumed to be nonreactive since they have filled valence shells. In 1962, Dr. Neil Bartlett at the University of British Columbia proved this assumption to be false.
Molecular Comparison of Gases, Liquids, and Solids

