Related Experiment Video
Updated: Jan 30, 2026

High-Throughput Cardiotoxicity Screening Using Mature Human Induced Pluripotent Stem Cell-Derived Cardiomyocyte Monolayers
Published on: March 24, 2023
Detection of anthracycline-induced cardiotoxicity using perfusion-corrected 99mTc sestamibi SPECT
Zaitulhusna M Safee1, Friedrich Baark1, Edward C T Waters1
1School of Biomedical Engineering and Imaging Sciences, London, UK.
Abstract:
By the time cardiotoxicity-associated cardiac dysfunction is detectable by echocardiography it is often beyond meaningful intervention. 99mTc-sestamibi is used clinically to image cardiac perfusion by single photon emission computed tomography (SPECT) imaging, but as a lipophilic cation its distribution is also governed by mitochondrial membrane potential (ΔΨm). Correcting scans for variations in perfusion (using a ΔΨm-independent perfusion tracer such as (bis(N-ethoxy-N-ethyldithiocarbamato)nitrido 99mTc(V)) (99mTc-NOET) could allow 99mTc-sestamibi to be repurposed to specifically report on ΔΨm as a readout of evolving cardiotoxicity. Isolated rat hearts were perfused within a γ-detection apparatus to characterize the pharmacokinetics of 99mTc-sestamibi and 99mTc-NOET in response to mitochondrial perturbation by hypoxia, ionophore (CCCP) or doxorubicin. All interventions induced 99mTc-sestamibi washout; hypoxia from 24.9 ± 2.6% ID to 0.4 ± 6.2%, CCCP from 22.8 ± 2.5% ID to -3.5 ± 3.1%, and doxorubicin from 23.0 ± 2.2% ID to 17.8 ± 0.7, p < 0.05. Cardiac 99mTc-NOET retention (34.0 ± 8.0% ID) was unaffected in all cases. Translating to an in vivo rat model, 2 weeks after bolus doxorubicin injection, there was a dose-dependent loss of cardiac 99mTc-sestamibi retention (from 2.3 ± 0.3 to 0.9 ± 0.2 ID/g with 10 mg/kg (p < 0.05)), while 99mTc-NOET retention (0.93 ± 0.16 ID/g) was unaffected. 99mTc-NOET therefore traps in myocardium independently of the mitochondrial perturbations that induce 99mTc-sestamibi washout, demonstrating proof-of-concept for an imaging approach to detect evolving cardiotoxicity.
Related Concept Videos
Distance Corrections
Power Factor Correction
NMR Spectrometers: Resolution and Error Correction
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Factors Affecting Drug Distribution: Organ Perfusion Rate